Sinopec News Network News To ensure the safe production of the canopy unit, the Tahe Refining & Petrochemical Refining Unit 2# Hydrogen Production Unit takes the "three implementations" as the starting point, firmly grasps safe production, and achieves both safe production and energy saving and consumption reduction.
Not wrong
.
Implement job safety responsibility system
2# Hydrogen production plant formulates a list of parts prone to over-temperature and over-pressure in summer, and establishes an independent inspection system to strengthen monitoring of each circulating pipeline and equipment that is prone to over-temperature and over-pressure
.
Regularly check the lead seals of the on-site pressure gauges and formulate solutions for over-temperature and over-pressure points
.
Implement equipment management system
Make full use of device weekly inspections and "references" investigations, in-depth summer safety inspections and direct operation link safety inspections, special inspections of "old scars", and use of day and night temperature differences to clean air cooling
.
Strengthen the frequency of roving inspections of key equipment, keep the cooling water of pumps and fans unblocked, prevent the lack of oil or deterioration of lubricating oil, increase the inspection of the cooling and lubrication systems of large units, and replace all the pumps and greases on site , Take multiple measures to eliminate hidden dangers of equipment defects
.
Implement cost reduction and efficiency enhancement system
Due to the high temperature during the day, the air-cooled variable frequency fans of some installations can no longer meet the cooling needs.
Therefore, the fixed frequency fans are used for air cooling when the temperature is high during the day, and the on-site fixed frequency fans are switched to when the temperature is relatively low at night.
The frequency conversion fan saves energy
.
The second is to wash all the air coolers with high pressure water, and use the low temperature period at night to switch the air coolers one by one to perform high pressure water washing to clean the blockages, salt-alkali scales, and debris in the tube bundles, and let the tube bundles take off.
A thick "sand coat" is used to ensure the cooling effect of the air cooler