echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Medical News > Latest Medical News > With regard to excipients and pharmaceutical packaging materials, the "Technical Requirements for Pharmaceutical Research of Chemical Inhalation Liquid Preparations" requires that...

    With regard to excipients and pharmaceutical packaging materials, the "Technical Requirements for Pharmaceutical Research of Chemical Inhalation Liquid Preparations" requires that...

    • Last Update: 2021-12-24
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com

    On November 26, the Center for Drug Evaluation of the National Food and Drug Administration issued the "Technical Requirements for Pharmaceutical Research on Inhaled Liquid Preparations of Chemical Drugs", including technical requirements for prescription technology, technical requirements for quality control of original and auxiliary packages, technical requirements for quality research and control, and stability studies And other parts put forward specific requirements for excipients and pharmaceutical packaging materials





    1.


    For excipients that are not used in domestic and foreign marketed inhalation products, used in changes of the route of administration, or used in excess of the conventional dosage, the safety support basis for the inhalation route should be provided, and the safety data of other routes of administration cannot be simply substituted



    For generic drugs, the type and amount of excipients in the prescription should usually be the same as that of the reference preparation.




    Production Process


    Technical requirements for quality control of original and auxiliary packages





    1.


    For generic drugs, the quality and performance of the packaging materials shall not be lower than the reference preparation in principle to ensure that the quality of the drug is consistent with the reference preparation
    .


    2.
    Packaging materials and containers in direct contact with drugs should comply with the packaging material standards issued by the State Food and Drug Administration, or the requirements of USP, EP, and JP
    .
     


    3.
    Refer to "Technical Guidelines for the Compatibility of Chemical Injections and Plastic Packaging Materials (Trial)", "Technical Guidelines for the Compatibility of Chemical Injections and Pharmaceutical Glass Packaging Containers (Trial)", "Chemicals and Elastomers" "Technical Guiding Principles for Research on the Compatibility of Seals (Trial)" and other relevant technical guiding principles to carry out studies on the compatibility of packaging materials and containers
    .

     For semi-permeable plastic ampoule packaging, the safety risk of the drug from the adhesive/ink extract in the label should be evaluated and researched
    .
     


    Quality research and control technical requirements

    Quality research


    Inhalation preparations are high-risk preparations.
    According to ICH Q3D, scientific and risk-based assessments are used to determine the control strategy of elemental impurities in the preparations, including the elemental impurities that may be introduced in the original and auxiliary packages and production equipment
    .


    Stability study


    1, semi-permeable formulation of the plastic packaging system should be based on the guidelines stability requirements, low humidity conditions Stability
    .
     


    2.
    Sterility inspection shall be carried out at the initial and final stages of the stability inspection.
    Other time points can be replaced by the sealing inspection of the packaging system
    .
     


    3.
    Carry out stability studies in use, such as the stability of the plastic ampoules after removing the outer packaging (including storage conditions and time), and reasonably formulate the storage conditions and service life after opening based on the research results
    .
     


    For more information, please visit: https://

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.