echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Active Ingredient News > Feed Industry News > Will the OC business close? Jiangsu Province issued the chemical industry safety rectification and upgrading work refinement requirements!

    Will the OC business close? Jiangsu Province issued the chemical industry safety rectification and upgrading work refinement requirements!

    • Last Update: 2020-08-02
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    recently, Jiangsu Province chemical industry safety and environmental protection promotion office office office issued a notice on the issuance of chemical industry safety and environmental protection promotion work related to the detailed requirements.
    zhG .The list of explosive-specific chemicals listed after the document includes 16 chemicals, including epoxy chloropropane and epoxy propane. Does this mean that all chemical concentration areas in Jiangsu Province, where the above-mentioned explosive properties are produced and used, will be shut down and withdrawn?
    zhG . the specific refinement requirements of thezhG are as follows:
    zhG(i) Close exit class (10)
    zhG 1. Listed in the products, technologies, processes and equipment that are phased out of the backward catalogue.
    zhG .2. Engage in the production and operation activities of hazardous chemicals without obtaining a safety production, use and business license in accordance with the law; construction projects of hazardous chemicals or installations in service fail to pass safety conditions, safety facility design review and inspection of safety facilities and the completion and acceptance of safety facilities.
    zhG .3. The chemical production plant has been parked for more than one year and there is an uncontrollable safety problem with the restart of the device.
    zhG .4. The fire department has determined that the chemical production enterprise sits as a major fire hazard and cannot complete the rectification.
    zhG .5. In the chemical concentration area confirmed by assessment, the production and use of chemical production enterprises or production equipment with explosive properties.
    zhG .6. A major accident of production safety occurred or was subject to major administrative penalties within twelve consecutive months a total of more than 3 times.
    zhG .7. Chemical production enterprises or production devices that fail to carry out essential safety diagnostic and management or fail to complete rectification through essential safety diagnosis and treatment.
    zhG .8. Chemical production enterprises that do not have safe production conditions, are highly toxic, flammable and explosive.
    zhG .9. Chemical production enterprises that constitute major hazardous sources of primary and secondary hazardous chemicals and the safety distance of important public buildings that do not meet relevant national standards.
    zhG .10. Chemical production enterprises that still do not have safe production conditions after production and rectification.
    zhG .(2) Discontinued rectification category (11)
    zhG 1. The device seduing the key supervision of the hazardous chemical process has not achieved automatic control, the system has not achieved the emergency stop function, and the automatic control system and emergency stop system of the equipment have not been put into use.
    zhG .2. The hazardous chemicals storage tank area has not set up the tank high and low level alarm in accordance with the relevant provisions, failed to use the ultra-high level automatic interlocking tank feed valve and ultra-low level automatic interlocking to stop the material transport measures;
    zhG .3. Control room or cabinet for the fire, explosion hazard device side does not meet the requirements of the national standard seislument explosion prevention, the production equipment involved in the nitrification hazard chemical process does not set up an area control room or central control room;
    zhG .4. The place involved in the leakage of flammable and toxic and harmful gases is not set up in accordance with the national standard sediconnection alarm device, the alarm signal is not sent to the control room or operating room;
    zhG .  5. The fire distance and external safety protection distance between the enterprise and the surrounding residential areas and important public buildings, railways and highways do not conform to the requirements of laws, regulations, standards and norms.
    zhG .  6. The process technology is from unknown sources and cannot provide the certificate of process safety and reliability, the chemical process first used in China has not been proved by the safety and reliability organized by the relevant departments of the provincial people's government, and the newly developed production of hazardous chemicals has been directly industrialized without small-test, pilot and industrialization tests.
    zhG .  7. In the process device may cause fire, explosion site is not set up in accordance with the provisions of over-temperature, overpressure and other detection instruments, sound and light alarm and safety interlocking device and other facilities.
    zhG .  8. By the end of 2019, enterprises have not established an integrated information management system such as monitoring information of major hazard sources, information of detection and alarm of flammable toxic gases, information on enterprise safety risk zoning, on-the-job information of production personnel and information on the management of the whole process of enterprise production.
    zhG .  9. The enterprise has not formulated the work system of security risk research and commitment announcement, has not appointed a person to be responsible for the investigation and evaluation of security risks, has not established the system of security risk investigation and risk control of the enterprise's full staff, full position and whole process, and has not set up a special section to publicize the contents of the enterprise security commitment announcement.
    zhG .  10. The filling of flammable and explosive, toxic and harmful liquefied gases such as liquefied hydrocarbons, liquid ammonia and liquid chlorine is not equipped with a universal pipe charging system. 11. The spherical storage tanks of propylene, propane, mixed carbon IV, extractcarbon iv and liquefied petroleum gas (LPG) and full-pressure liquefied hydrocarbon storage tanks were not equipped with water injection measures in accordance with national standards.
    zhG .  (3) The
    zhG 1. The actual controller has not acted as the legal representative; the principal person in charge does not have more than 3 years of experience in the chemical industry or does not have a college degree or above. Of the principals in charge of chemical enterprises and persons in charge of safety and production, none has a college degree or above in the National Education and Chemical Industry, or has the technical title of senior engineer of chemical industry;
    zhG .  2. The main person in charge of the chemical enterprise, the person in charge of technology, the person in charge of safety and the full-time safety management personnel have passed the examination without the training and examination of the practicing ability;
    zhG .  3. The operators engaged in hazardous operations do not meet the basic conditions of practice; special operations personnel who have passed the qualification certificate for special operations without training and examination of their ability to practise practice; and those engaged in special equipment operations and management have not obtained the corresponding qualification certificate for special equipment operationpers.
    zhG .  4. The number of full-time safety production management personnel is less than 2% of the total number of employees stipulated in the Regulations on Safe Production in Jiangsu Province. Less than 15% of registered safety engineers are available (less than 7 full-time safety managers with at least 1 person).
    zhG .  5. The responsibility system for safe production covering all departments and personnel has not been established, and the rules and regulations and operating procedures for safe production have not been formulated and revised in a timely manner. 6. Chemical production enterprises involved in the production of hazardous chemicals, hazardous chemical processes or the production and use of explosive chemicals have not achieved secondary standardization.
    zhG .  7. Highly toxic gases such as light gas and chlorine gas and hydrogen sulfide gas pipelines pass through public areas except the plant (including chemical parks and industrial parks).
    zhG .  8. Regional overhead power lines cross production areas and do not meet the requirements of national standards.
    zhG .  9. The emergency relief materials are not in line with the requirements for emergency relief materials for hazardous chemical units.
    zhG .  10. Fine chemical enterprises have not carried out a reaction safety risk assessment as required by the normative documents.
    zhG .  11. Chemical production equipment did not set up dual power supply according to national standards, automatic control system did not set up uninterruptible power supply.
    zhG .  Ii. Noun seunt interpretation
    zhG (i) Chemicals with explosive properties refer to ethylene oxide, epoxy propane, epoxy chloropropane, peroxy acetic acid, methyl acetone peroxide, benzoyl oxide, cellulose, metformin, nitric acid, nitric acid, Benzopentine peroxide, nitroquine, N, N'-di nitro-imethyltetraamine, 2,2'-azo-diazepam, azo diazepam, nitrogen glycerin, nitrobenzene, ammonium nitrate and other 16 chemicals.
    zhG .  (2) Major administrative penalties refer to the administrative penalty of ordering an enterprise to stop production and rectify, order to stop production and stop construction, order to stop construction, order to stop construction, revoke the relevant license, revoke the relevant qualification or post certificate, impose a fine of more than 50,000 yuan, confiscate illegal income, confiscate illegally mined coal products or mining equipment worth more than 50,000 yuan. (3) The actual controller of the company means a person who is not a shareholder of the company but is able to actually control the company's behavior through investment relations, agreements or other arrangements. (4) Overhead power lines in area overhead power lines refer to overhead power lines with voltage levels generally above 35kV.
    zhG
    recently, Jiangsu Province chemical industry safety and environmental protection promotion office office office issued a notice on the issuance of chemical industry safety and environmental protection promotion work related to the detailed requirements.
    zhG .  The list of explosive-specific chemicals listed after the document includes 16 chemicals, including epoxy chloropropane and epoxy propane. Does this mean that all chemical concentration areas in Jiangsu Province, where the above-mentioned explosive properties are produced and used, will be shut down and withdrawn?
    zhG . the specific refinement requirements of the zhG are as follows:
    zhG (i) Close exit class (10)
    zhG 1. Listed in the products, technologies, processes and equipment that are phased out of the backward catalogue.
    zhG .  2. Engage in the production and operation activities of hazardous chemicals without obtaining a safety production, use and business license in accordance with the law; construction projects of hazardous chemicals or installations in service fail to pass safety conditions, safety facility design review and inspection of safety facilities and the completion and acceptance of safety facilities.
    zhG .  3. The chemical production plant has been parked for more than one year and there is an uncontrollable safety problem with the restart of the device.
    zhG .  4. The fire department has determined that the chemical production enterprise sits as a major fire hazard and cannot complete the rectification.
    zhG .  5. In the chemical concentration area confirmed by assessment, the production and use of chemical production enterprises or production equipment with explosive properties.
    zhG .  6. A major accident of production safety occurred or was subject to major administrative penalties within twelve consecutive months a total of more than 3 times.
    zhG .  7. Chemical production enterprises or production devices that fail to carry out essential safety diagnostic and management or fail to complete rectification through essential safety diagnosis and treatment.
    zhG .  8. Chemical production enterprises that do not have safe production conditions, are highly toxic, flammable and explosive.
    zhG .  9. Chemical production enterprises that constitute major hazardous sources of primary and secondary hazardous chemicals and the safety distance of important public buildings that do not meet relevant national standards.
    zhG .  10. Chemical production enterprises that still do not have safe production conditions after production and rectification.
    zhG .  (2) Discontinued rectification category (11)
    zhG 1. The device seduing the key supervision of the hazardous chemical process has not achieved automatic control, the system has not achieved the emergency stop function, and the automatic control system and emergency stop system of the equipment have not been put into use.
    zhG .  2. The hazardous chemicals storage tank area has not set up the tank high and low level alarm in accordance with the relevant provisions, failed to use the ultra-high level automatic interlocking tank feed valve and ultra-low level automatic interlocking to stop the material transport measures;
    zhG .  3. Control room or cabinet for the fire, explosion hazard device side does not meet the requirements of the national standard seislument explosion prevention, the production equipment involved in the nitrification hazard chemical process does not set up an area control room or central control room;
    zhG .  4. Involves flammable and toxic and harmful gas leakage.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.