    Home > Active Ingredient News > Drugs Articles > What to look out for when using a used liquid chromatography mass spectrometer

    What to look out for when using a used liquid chromatography mass spectrometer

    • Last Update: 2022-09-14
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    The USED Liquid Chromatograph SCIEX 4500 system intelligently modifies the API 4000 platform to set a new set for reliable quantitative analysis – 10 times
    more sensitive than comparable triple quadrupole products.

    The intelligently modified 4500 system is a major player in the LC-MS/MS space
    .

    Focusing on ADME, regulatory bioanalysis, food and environmental contaminant screening, targeted quantitative proteomics, or clinical research, the Triple Quad 4500 system delivers excellent performance
    in key metrics.

    Requirements for the use of second-hand liquid chromatography mass spectrometer: 1.
    The mobile phase must be filtered with HPLC-level reagents to remove particulate impurities and other substances (using a membrane filtration of 0.
    45 μm or finer).
    2, mobile phase filtration to use ultrasonic degassing, after degassing should be restored to room temperature after use
    .

    3, can not use pure acetonitrile as a mobile phase, which will make the check valve stick and cause the pump not to enter the liquid
    .

    4.
    When using buffer solution, immediately after making the sample, rinse the pipeline and column with deionized water for one hour, and then rinse with methanol (or methanol aqueous solution) for more than 40 minutes to fully wash ionized
    .

    For the outside of the plunger rod, it is also necessary to rinse more than
    20 mL with deionized water after the sample is done.

    5, a long time without instruments, should be removed from the column with a plug sealed for preservation, pay attention to the fact that the column can not be preserved with pure water, but should use the organic phase (such as methanol, etc.
    ), because pure water is easy to grow mold
    .

    6.
    After each sample, the injector
    should be cleaned with a solvent that dissolves the sample.

    7.
    C18 column cannot enter protein samples, blood samples, and biological samples
    .

     
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.