Sand dust test chamber is suitable for testing the shell sealing performance of the product, sand dust test chamber in the process of testing, may be due to operational errors, power failure and other reasons caused by sand dust test box operation failure
.
1.
The equipment is not ----- check whether the power supply is normal, check whether the phase sequence is normal, whether there is a zero line, whether the circuit breaker is closed, whether the fuse is normal 2.
Do not blow dust------ check whether the blower is working properly or the fan is too small, check whether the dust is dry 3.
Do not vibrate----- check whether the vibration motor is normal 4.
The instrument shows garbled code----- restart or replace the new instrument The above inspection should be carried out by a professional (or under the guidance of the manufacturer's technicians).
, can be used table, pay attention to personal safety, such as found damage should be replaced
in time.