    What are the refrigeration and heating effects of reactor high and low temperature control

    • Last Update: 2022-09-14
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    The reactor high and low temperature control is very compatible with the working temperature required for the production and heating equipment in the pharmaceutical, chemical and other industries, and the operation is safe
    .

    1, high thermal conductivity efficiency, the use of heat transfer oil through the heat conduction of the heater to cool down the heat energy to achieve the purpose of heating, is a closed circulation system, so there is no heat loss, so the thermal efficiency is high effect.
    2, in the circulation of heating, because there is no gas phase pressure, so that the material strength and sealing requirements of the equipment used can be reduced, which is conducive to reducing the equipment manufacturing and use costs
    .

    And can easily meet the production process requirements temperature
    .

    3, when the process requires temperature, the use of saturated industrial steam heating, its steam pressure to meet the requirements, it can be seen that the strength and sealing performance requirements of the materials used in the steam heating equipment will be heat transfer oil heating equipment
    .

    4, in the chemical reaction, the supporting reactor used in the stirrer for the speed of the requirements, the motor is mainly to adapt to the reducer for the entire movement process of the stirring
    .

    The reducer is vertically installed to ensure that the lubrication is in good condition, there is no vibration, leakage, and has been in a normal state, which requires strengthening daily maintenance control
    .

    The main reason for the vibration of the reducer during the rotation is that the following aspects need to be adjusted
    in time for these aspects.

    5, the electric heater is installed in the inner part of the body near the lower position of the fuel tank, and the side of the electric heater is provided with an oil pump, the side of the oil pump is provided with a cooler, the side of the solenoid valve is provided with a filter, and the internal of the solenoid valve is provided with a coolant inlet in the rear position of the body, the coolant inlet is provided with a heating liquid outlet, the lower part of the heating liquid outlet is provided with a coolant outlet, and the end of the temperature alarm is set with a temperature-sensitive head.
    And the temperature alarm side near the upper end of the tank is provided with an oil filling port, the electric heater is provided with a heating tube, the electric heater, oil pump, cooler, solenoid valve and temperature alarm are connected
    to the control panel through the wire.

     
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.