    What are the debugging methods of oral liquid filling machine?

    • Last Update: 2022-05-06
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com

    The adjustment method of Shanghai Shenggang oral liquid filling machine has the following steps: 1.
    Adjustment of the feeding half 1.
    Adjust the bottle blocking plate A on the feeding half upward to shorten the bottle feeding stroke; downward adjustment, Extend the bottle feeding stroke
    .

    2.
    Adjust the positioning bottle position left and right so that the movable teeth are aligned with the bottle position when running, so that the bottle can be smoothly fed into the positioning teeth
    .

    3.
    Adjust the bottle blocking plate B so that the width of the bottle inlet is about 22 mm
    .

    2.
    The function of the perfusion component to adjust the perfusion component is to transport the liquid medicine to each easy-pull bottle in time through the medicine dispenser, the one-way valve and the needle, so the needle must be properly entered into the bottle mouth, and the filling time must be appropriate.

    .

      1.
    Adjust the side cam A to rotate forward or reverse so that the needle is inserted into the bottle mouth just after the empty bottle enters the toothed position
    .

    and lift the needle before leaving the toothed position
    .

      2.
    Perfusion time adjustment: Turn cam B forward or reverse to adjust the injection to start immediately after the needle enters the bottle mouth, and stop the injection before the needle leaves the bottle mouth
    .

      3.
    Adjustment of liquid volume: loosen nut 1 and adjust the ejector rod in the direction of D, the liquid volume will increase; adjust the liquid volume in the C direction to reduce the liquid volume, and adjust the nut 2 in the F direction to reduce the liquid volume, and adjust it in the E direction to increase the liquid volume When adjusting, pay attention to the limit position of the drug injector to avoid damage to the drug injector.
    Generally, it is advisable that the bottom of the drug injector reaches the drug spit not less than 15 mm, and the longer the perfusion time, the better
    .


    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.