-
Categories
-
Pharmaceutical Intermediates
-
Active Pharmaceutical Ingredients
-
Food Additives
- Industrial Coatings
- Agrochemicals
- Dyes and Pigments
- Surfactant
- Flavors and Fragrances
- Chemical Reagents
- Catalyst and Auxiliary
- Natural Products
- Inorganic Chemistry
-
Organic Chemistry
-
Biochemical Engineering
- Analytical Chemistry
-
Cosmetic Ingredient
- Water Treatment Chemical
-
Pharmaceutical Intermediates
Promotion
ECHEMI Mall
Wholesale
Weekly Price
Exhibition
News
-
Trade Service
The "oil separator" in the high and low temperature humid heat test chamber can separate the oil in the exhaust gas and reduce the oil intake of the system, because it has a great influence on the heat transfer of the system, especially the evaporator.
It will condense in the pipeline, which is not conducive to heat transfer.
After the automatic system oil separation, it must slip back to the crankcase to prevent the compressor from running out of oil
.
There is an oil separator between the compressor and the cooler of Aipei Technology, and the exhaust of the compressor contains refrigerating oil, so the oil separator is used to separate the refrigerating oil entrained in the refrigerant vapor.
, so that the refrigeration oil returns to the compressor crankcase
.
Refrigeration oil enters the refrigeration system with the refrigerant, especially after entering the condenser and evaporator, an oil film will be formed on the heat transfer surface, which will affect the heat exchange effect of the heat exchange equipment, and easily cause oil blockage in the expansion valve and capillary tube.
If the oil return of the system is not good, it is very likely to cause the compressor to lack oil and cause the compressor coil to burn out or the cylinder block to be damaged
.
Therefore, whether it is a high-quality and reasonable refrigeration oil directly affects the life of the high and low temperature damp heat test chamber
.
It can be seen that reliable oil separator and refrigeration oil are very important for the high and low temperature damp heat test chamber
.
It will condense in the pipeline, which is not conducive to heat transfer.
After the automatic system oil separation, it must slip back to the crankcase to prevent the compressor from running out of oil
.
There is an oil separator between the compressor and the cooler of Aipei Technology, and the exhaust of the compressor contains refrigerating oil, so the oil separator is used to separate the refrigerating oil entrained in the refrigerant vapor.
, so that the refrigeration oil returns to the compressor crankcase
.
Refrigeration oil enters the refrigeration system with the refrigerant, especially after entering the condenser and evaporator, an oil film will be formed on the heat transfer surface, which will affect the heat exchange effect of the heat exchange equipment, and easily cause oil blockage in the expansion valve and capillary tube.
If the oil return of the system is not good, it is very likely to cause the compressor to lack oil and cause the compressor coil to burn out or the cylinder block to be damaged
.
Therefore, whether it is a high-quality and reasonable refrigeration oil directly affects the life of the high and low temperature damp heat test chamber
.
It can be seen that reliable oil separator and refrigeration oil are very important for the high and low temperature damp heat test chamber
.