    In addition to the correct design, the use effect of the laboratory air-purifying fume hood is also closely related to the rational use and maintenance.
    Therefore, the following points should be paid attention to: (1) During the experiment, harmful The experimental device of the clean air fume hood should be placed in a place where the operation opening of the cabinet is larger than 150MM to prevent the overflow of harmful substances; (2) The experimental device of the clean air fume hood should not block the exhaust slit; (3) Experiment After finishing, the fan should not be turned off immediately, and it should be turned off after 3 to 5 minutes; (4) The clean air fume hood should not be used as a storage cabinet; (5) The inside of the clean air fume hood should always keep the inner surface of the cabinet smooth and clean.
    If it is damaged, it must be repaired in time; (6) The ventilator, air duct and related accessories should be inspected regularly
    .

    (7) The fume hood must be measured and adjusted every once in a while; make the clean air fume hood operate under the design conditions; (8) The temperature in the clean air fume hood, such as an electric furnace with a large wattage, should be cushioned.
    The backing plate should not be stored and opened for a long time, so as not to affect the use of the clean air fume hood
    .


    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.