    The EK1914 EtherCAT coupler combines
    the functionality of the EK1100 EtherCAT coupler with standard and safe digital I/O.
    This results in a compact design that is ideal for applications
    with small amounts of I/O.
    Like the EK1100, the EK1914 can be extended to all EL/ES terminals
    .
    The EK1914 has four digital inputs and four digital outputs, as well as two fail-safe inputs and two fail-safe outputs
    .
    The safe input and output signals are exchanged
    via FSoE with components with TwinSAFE logic.
    The EK1914 has safety parameters that allow functions to be specially adapted to the respective safety requirements (e.
    g.
    input 1-channel evaluation vs.
    2-channel evaluation, testing of individual channels).

    In addition, standard output
    can be activated for the EK1914.
    Thus, the corresponding standard output can be performed in parallel with the safety output of the EK1914 and internally with the safe output
    .
    The safety output signal controlled by the TwinSAFE Logic thus emits a safe release for the standard signal, which can then be triggered by a non-safety-oriented control system, independent of the safety controller and the FSoE cycle
    .
    This allows for faster output switching times, provided that the safety controller issues the necessary release
    for the output.
    The safety parameters are not stored directly on the component, but are transmitted to the input terminal
    via the component with the TwinSAFE Logic function when the security application is started.
    This simplifies the service procedure, as the components
    can simply be replaced in this case.
    When the security application is restarted, the safety-related parameters are transferred to the new component
    .
    Special features: EtherCAT coupler with integrated I/O (standard and safe) Two safety inputs Two safety outputs cross-circuit detection directly on the component 1-channel and 2-channel evaluation input channels can be activated individually Standard output can be activated via integrated ANDing with safe output signalActivation of productsInformation technology data accessoriesSoftware documentation and download media libraryRelated product technical data Housing data reaching the apex technical data EK1914 connection technology 1-/2- Line specification EtherCAT coupler input number with standard and safety I/O Number of 6 digital inputs, of which 2 are fail-safe input and output count6 digital outputs, of which 2 are fail-safe output maximum
    。 Output current per standard output: 0.
    5 A, each safety output: 0.
    5 A, min.
    20 mA protocol EtherCAT fault response time≤ Safety standard for watchdog time installation position levels DIN EN ISO 13849-1:2008 (Class 4, PL e) Weight approx.
    123 g IP protection class IP20 technical data Housing data reaches the apex of housing data EK-44-16pin design form with signal LED HD (High Density) Housing Material Polycarbonate Dimensions (W x H x D) 44 mm x 100 mm x 67 mm mounted on a 35 mm DIN rail according to EN 60715 Label wiring with lock marking BZxxx series by side-by-side mounting double slot and key connection solid conductors (e): direct plug-in technique; fine-stranded conductors (f) and ferrule (a): spring actuation by screwdriverConnection cross-sections*: 0.
    08.
    .
    .
    1.
    5 mm²,st*: 0.
    25.
    .
    .
    1.
    5 mm²,f*: 0.
    14.
    .
    .
    0.
    75 mm²Connection cross-section AWGs*: AWG 28.
    .
    .
    16,st*: AWG 22.
    .
    .
    16,f*: AWG 26.
    .
    .
    19Stripping length8.
    .
    .
    9 mmCurrent load power contactsImax: 10 A
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.