The Chinese medicine juice extraction machine uses the extraction equipment to extract the essence ingredients in Chinese medicine
.
The equipment components can be divided into extraction tanks, condensers, coolers, separators, filters, pneumatic control systems for
slag outlet doors, etc.
According to the different needs of users, the process requirements of the design and production, Chinese medicine extraction equipment is widely used in traditional Chinese medicine, plants, food, biology, light chemical industry atmospheric pressure, pressurization, decompression, extraction, warm immersion, heat reflux, forced circulation, seepage, separation of aromatic oil and recovery
of organic solvents.
The Chinese medicine juice extractor is specifically controlled by the following stages: Amount of solvent fed: The set amount
of ethanol or purified water added each time.
Holding time: The time set
for each heat holding decoction after heating up.
Discharge: The output amount set
at the end of each insulation.
Insulation steam pressure: The target pressure value
is automatically adjusted by the steam control valve in the insulation stage.
Open cycle time: the time of the cycle during heating and heat preservation
.
Standing time: The time to let stand before the outlet
is left.
Clogging flushing time: Judged as automatic flushing time
after blocking.
Off cycle time: cycle interval time
during heating and heat preservation.
Heating temperature: Heat up to the target value into the insulation
.
Heating steam pressure: The target pressure value
is automatically adjusted by the steam control valve during the heating phase.
Effluent End Low Flow: The effluent volume reaches the set extract effluent and the flow rate is less than the end low flow effluent end
.
Protective pressure in the tank: the pressure in the tank exceeds the protective value during the heating and insulation process and automatically opens the empty valve
.
Low flow rate: The amount of effluent does not reach the set amount of extracted liquid, and the flow rate is less than that of the low flow of blockage
.
Steam protection pressure: Steam pressure exceeding the protective pressure during heating and heat preservation automatically closes the steam regulating valve
.
Protective pressure in the tank: The temperature reaches the set protective temperature during the insulation process and automatically closes the steam regulating valve
.