LAMBDA visible spectrophotometer powerful data analysis function, the host can complete photometric measurement, quantitative measurement, spectral scanning, kinetics, DNA/protein testing, multi-wavelength testing and data printing functions; Adopting optical system suspension design, the overall optical path is independently fixed on a 16mm thick aluminum non-deformation base, and the deformation of the bottom plate and external vibration do not have any effect on the optical system, thereby improving the stability and reliability
of the instrument.
The main components adopt imported configuration, which makes the instrument stray light lower, stable and more reliable; Scanning software, when operating online, can not only realize all the test functions of the host, but also realize more powerful data processing functions
.
The specific requirements of the LAMBDA visible spectrophotometer installation environment are as follows: 1.
The ambient temperature and humidity instrument should be placed in a dry room, the use temperature is 5~35 °C, the relative humidity does not exceed 85%, it is recommended that it should be controlled at 45%~65%, without condensation
.
If possible, it should be equipped with a dehumidifier (air conditioning), hygrometer, etc.
, and some desiccant should be placed around the instrument in areas with high relative humidity
.
2
.
No strong light interference and magnetic field interference indoor lighting should not be too strong, and avoid direct sunlight.
The instrument should be as far away as possible from high-intensity magnetic fields, electric fields and electrical equipment that generate high-frequency waves to prevent electromagnetic interference
.
3.
Prevent corrosive gases from being used in places such as sulfur dioxide and various acid mist, so as not to erode the approximate parts
of the instrument.
LAMBDA visible spectrophotometer before starting the instrument, must take out the moisture-proof agent stored in the sample room, when the instrument is normally operated for inspection, must not open the sample chamber cover, the liquid in the cuvette is required to account for 66%-80% of the total volume, can not let too much liquid, so that the liquid leakage corrosion instrument, normal detection, need to ensure that the cuvette is clean, the droplets on the inner wall need to be wiped with professional paper, must not be wiped directly by hand, It is easy to cause injury
to the hands of the user.