Read this manual carefully before use
.
This ELISA kit is based on the principle of double-antibody sandwich technology to detect free insulin-like growth factor 1 (Free IGF-1) in rats, which can only be used for research purposes, not for medical diagnosis
.
Application: Used for the determination of free insulin-like growth factor 1 (Free IGF-1) in rat serum, plasma and related liquid samples
.
Working principle
This kit uses biotin double antibody sandwich enzyme-linked immunosorbent assay (ELISA) to determine the level of rat free insulin-like growth factor 1 (Free IGF-1) in the sample
.
Add rat free insulin-like growth factor 1 (Free IGF-1) to the enzyme-labeled wells pre-coated with rat free insulin-like growth factor 1 (Free IGF-1) monoclonal antibody, and incubate; Afterwards, biotin-labeled anti-free insulin-like growth factor 1 (Free IGF-1) antibody was added
.
It is then combined with streptavidin-HRP to form an immune complex, which is then incubated and washed to remove unbound enzymes, and then substrates A and B are added to produce blue color, which is converted into the final product under the action of acid.
of yellow
.
The shade of color was positively correlated with the concentration of rat free insulin-like growth factor 1 (Free IGF-1) in the sample
.
Kit composition
Reagents and equipment required but not provided
Precautions
Plate washing method
Manual plate washing method: shake off the liquid in the ELISA plate; lay a few layers of absorbent paper on the test bench, and tap the ELISA plate downward several times; inject at least 0.
35ml of the diluted washing solution into the well, Soak for 1-2 minutes
.
Repeat this process as many times as necessary
.
Automatic plate washing: If there is an automatic plate washing machine, it should be used in the formal experiment process after skilled use.
Specimen requirements
1.
Samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity
.
2.
The extraction should be carried out as soon as possible after the specimen collection, and the extraction should be carried out according to the relevant literature
.
If the test cannot be performed immediately, the specimen can be stored at -20°C, but repeated freezing and thawing should be avoided
.
operating procedure
Kit performance:
1.
The R value of the correlation coefficient between the linear regression of the sample and the expected concentration is above 0.
92
.
2.
Intra-batch and inter-batch should be less than 9% and 15% respectively.
Detection range:
detection range: 0.
25 ng/ml -9ng/ml
Storage conditions and validity period:
storage: 2-8 ℃
.
Validity period: 6 months (2-8℃)
.
.
This ELISA kit is based on the principle of double-antibody sandwich technology to detect free insulin-like growth factor 1 (Free IGF-1) in rats, which can only be used for research purposes, not for medical diagnosis
.
Application: Used for the determination of free insulin-like growth factor 1 (Free IGF-1) in rat serum, plasma and related liquid samples
.
Working principle
This kit uses biotin double antibody sandwich enzyme-linked immunosorbent assay (ELISA) to determine the level of rat free insulin-like growth factor 1 (Free IGF-1) in the sample
.
Add rat free insulin-like growth factor 1 (Free IGF-1) to the enzyme-labeled wells pre-coated with rat free insulin-like growth factor 1 (Free IGF-1) monoclonal antibody, and incubate; Afterwards, biotin-labeled anti-free insulin-like growth factor 1 (Free IGF-1) antibody was added
.
It is then combined with streptavidin-HRP to form an immune complex, which is then incubated and washed to remove unbound enzymes, and then substrates A and B are added to produce blue color, which is converted into the final product under the action of acid.
of yellow
.
The shade of color was positively correlated with the concentration of rat free insulin-like growth factor 1 (Free IGF-1) in the sample
.
Kit composition
Kit composition | 48 well configuration | 96-well configuration | save |
manual | 1 serving | 1 serving | |
Sealing film | 2 pieces (48) | 2 pieces (96) | |
sealed bag | 1 | 1 | |
ELISA coated plate | 1×48 | 1×96 | Store at 2-8°C |
Standard 16ng/ml | 0. 5ml×1 bottle |
0. 5ml×1 bottle |
Store at 2-8°C |
Standard Diluent | 3ml×1 bottle | 6ml×1 bottle | Store at 2-8°C |
Streptavidin-HRP | 3 ml×1 bottle | 6 ml×1 bottle | Store at 2-8°C |
Biotinylated Anti-HbA1 Antibody | 0. 5ml×1 bottle |
1 ml×1 bottle | Store at 2-8°C |
Color developer liquid A | 3 ml×1 bottle | 6 ml×1 bottle | Store at 2-8°C |
Color developer liquid B | 3 ml×1 bottle | 6 ml×1 bottle | Store at 2-8°C |
Stop solution | 3ml×1 bottle | 6ml×1 bottle | Store at 2-8°C |
Concentrated washing liquid | (20ml × 20 times) × 1 bottle | (20ml × 30 times) × 1 bottle | Store at 2-8°C |
Reagents and equipment required but not provided
- 37°C incubator
. - Standard specification microplate reader
. - Precision pipettes and disposable tips
- distilled water,
- disposable test tube
- Absorbent paper
Precautions
- Remove the kit from 2-8°C and equilibrate at room temperature for at least 30 minutes before opening the kit
.
If the enzyme-labeled plate is not used up after opening, the slats should be stored in a sealed bag
. - A sampler should be used for each step of sample addition, and its accuracy should be checked frequently to avoid experimental errors
- Strictly follow the instructions in the instructions, and the test results must be determined by the reading of the microplate reader.
- To avoid cross-contamination, avoid reusing tips and sealing membranes in your hands
. - Other reagents not in use should be packaged or covered
.
Do not mix reagents from different batches
.
Use before warranty
. - Substrate B is sensitive to light, avoid prolonged exposure to light
.
Plate washing method
Manual plate washing method: shake off the liquid in the ELISA plate; lay a few layers of absorbent paper on the test bench, and tap the ELISA plate downward several times; inject at least 0.
35ml of the diluted washing solution into the well, Soak for 1-2 minutes
.
Repeat this process as many times as necessary
.
Automatic plate washing: If there is an automatic plate washing machine, it should be used in the formal experiment process after skilled use.
Specimen requirements
1.
Samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity
.
2.
The extraction should be carried out as soon as possible after the specimen collection, and the extraction should be carried out according to the relevant literature
.
If the test cannot be performed immediately, the specimen can be stored at -20°C, but repeated freezing and thawing should be avoided
.
operating procedure
- Dilution of the standard: (This kit provides a standard of original times, and the user can dilute it in a small test tube according to the following chart
.
)
8ng/ml | Standard No. 5 |
Add 120μl of standard dilution to 120μl of double standard |
4ng/ml | Standard No. 4 |
Add 120 μl of standard No. 5 to 120 μl of standard dilution |
2ng/ml | Standard No. 3 |
Add 120μl of standard No. 4 to 120μl of standard dilution |
1ng/ml | Standard No. 2 |
Add 120μl of standard No. 3 to 120μl of standard dilution |
0. 5ng/ml |
Standard No. 1 |
Add 120μl of standard No. 2 to 120μl of standard dilution |
- Determine the number of strips required based on the number of samples to be tested plus the number of standards
.
Duplicate wells are recommended for each standard and blank well
.
Each sample is determined according to its own quantity, and those that can use duplicate holes should be made as duplicate holes as possible
. - Add sample: 1) Blank well, blank control well without sample, biotin-labeled anti-HbA1 antibody, streptavidin-HRP, only add chromogen A&B and stop solution, the rest of the steps are the same; 2) Standard Well: add 50ul of standard product, 50ul of streptavidin-HRP (biotin antibody has been integrated in standard product, so it is not added); 3) Sample well to be tested: add 40ul of sample, and then add 10ul of anti-HbA1 antibody to each well , Streptavidin-HRP 50ul, cover with sealing film, gently shake and mix, and incubate at 37°C for 60 minutes
. - Dosing: Dilute the 30-fold concentrated washing solution with distilled water 30-fold for later use
. - Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with washing solution, let stand for 30 seconds, and then discard, repeat this process 5 times, and pat dry
. - Color development: Add 50ul of color developer A to each well, then add 50 μl of color developer B, gently shake and mix, and develop color at 37°C for 15 minutes in the dark.
- Termination: Add 50 μl of stop solution to each well to stop the reaction (the blue turns to yellow at this time)
. - Determination: Zero the blank well, and measure the absorbance (OD value) of each well in sequence at a wavelength of 450 nm
.
The measurement should be carried out within 10 minutes after adding the stop solution
. - Calculate the linear regression equation of the standard curve according to the concentration of the standard product and the corresponding OD value, and then calculate the corresponding sample concentration on the regression equation according to the OD value of the sample
.
It can also be calculated using various application software
.
Kit performance:
1.
The R value of the correlation coefficient between the linear regression of the sample and the expected concentration is above 0.
92
.
2.
Intra-batch and inter-batch should be less than 9% and 15% respectively.
Detection range:
detection range: 0.
25 ng/ml -9ng/ml
Storage conditions and validity period:
storage: 2-8 ℃
.
Validity period: 6 months (2-8℃)
.