    Radiology: Dual-energy CT perfusion, making imaging at the forefront of non-small cell lung cancer evaluation!

    • Last Update: 2022-01-23
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com

    Tumor growth is a complex process that requires tissue vascular supply for nutrients and oxygen uptake
    .


    This process is greatly affected by hypoxia and can induce abnormal vascularization and epithelial-mesenchymal transition, both of which are conducive to the metastatic spread of cancer cells


    Tumor growth is a complex process that requires tissue vascular supply for nutrients and oxygen uptake


    Dual-energy CT provides an interesting approach for assessing angiogenic aspects of lung tumors .
    Several recently published studies have shown that dual-energy CT can obtain mean iodine concentration measurements throughout the tumor volume to predict the effect of tumor chemotherapy and further reflect its relationship with postoperative prognosis .
    Dual-energy CT can obtain mean iodine concentration measurements throughout the tumor volume to predict the effect of tumor chemotherapy and further reflect its relationship with postoperative prognosis .
    However , to the best of our knowledge, studies on the relationship between lung tumor hypoxia and dual-energy CT parameters are still insufficient .

    Recently, a study published in the journal Radiology analyzed the dual-energy CT perfusion characteristics of non-small cell lung cancer according to the degree of tumor hypoxia, providing more intuitive imaging support for the evaluation of the efficacy and prognosis of lung cancer
    .

    Recently, a study published in the journal Radiology analyzed the dual-energy CT perfusion characteristics of non-small cell lung cancer according to the degree of tumor hypoxia, providing more intuitive imaging support for the evaluation of the efficacy and prognosis of lung cancer
    .


    This prospective study performed two -phase dual-energy CT scans in consecutive participants with operable non-small cell lung cancer during 2016-2017 .


    Transient and delayed iodine concentrations and normalized iodine uptake were calculated for the entire tumor and within three automatically segmented peripheral layers (i.
    e.
    , 2 mm thick concentric subvolumes), corresponding to the intratumoral iodine concentration normalized to the primary iodine concentration.
    Iodine concentration in arteries .


    This prospective study performed two -phase dual-energy CT scans in consecutive participants with operable non-small cell lung cancer during 2016-2017 .
    Transient and delayed iodine concentrations and normalized iodine uptake were calculated for the entire tumor and within three automatically segmented peripheral layers (i.
    e.
    , 2 mm thick concentric subvolumes), corresponding to the intratumoral iodine concentration normalized to the primary iodine concentration.
    Iodine concentration in arteries .


    There were 33 mCA IX-positive tumors and 16 mCA IX-negative tumors


     

    Figure 79-year-old female with adenocarcinoma of the right upper lobe who underwent dual-energy CT angiography scan before surgery .
    (A) Mediastinum and (B) corresponding lung CT slices were obtained at the level of maximum tumor diameter , showing tumor segmentation .
    Segmented tumor volumes are shown in purple .
     

    Figure 79-year-old female with adenocarcinoma of the right upper lobe who underwent dual-energy CT angiography scan before surgery .


    (A) Mediastinum and (B) corresponding lung CT slices were obtained at the level of maximum tumor diameter , showing tumor segmentation .
    Segmented tumor volumes are shown in purple .
    Figure 79-year-old female with adenocarcinoma of the right upper lobe who underwent dual-energy CT angiography scan before surgery .
    (A) Mediastinum and (B) corresponding lung CT slices were obtained at the level of maximum tumor diameter , showing tumor segmentation .
    Segmented tumor volumes are shown in purple .
     

     

    In conclusion, this study demonstrates that dual- phase dual-energy CT examination can provide information on lung tumor perfusion by identifying functional neovascular areas between lung parenchyma and tumor , enabling in vivo insight into the forefront of tumor invasion , providing insights into tumor invasion in vivo.


    Treatment and evaluation provide a reference basis .


    In conclusion, this study demonstrates that dual- phase dual-energy CT examination can provide information on lung tumor perfusion by identifying functional neovascular areas between lung parenchyma and tumor , enabling in vivo insight into the forefront of tumor invasion , providing insights into tumor invasion in vivo.
    Treatment and evaluation provide a reference basis .


    Original source :

    Original source :

    Julie Dewaguet , Marie-Christine Copin , Alain Duhamel , et al.


    Dual-Energy CT Perfusion of Invasive Tumor Front in Non-Small Cell Lung Cancers.


    Julie Dewaguet Marie-Christine Copin Alain Duhamel 10.
    1148/radiol.
    2021210600.
    Leave a comment here
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.