    Precautions for installation and use of laboratory small refrigeration units

    • Last Update: 2022-05-03
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    There are some things to pay attention to when installing small laboratory refrigeration units, because the installation precautions of different types of small laboratory refrigeration units are also different, so what should you pay attention to? Precautions for the installation of small laboratory refrigeration units: 1.
    The installation location of small laboratory refrigeration units needs to lay a solid foundation on the ground before installation to ensure the ground level; 2.
    There are certain differences in parameter configuration between different types of small laboratory refrigeration units , the diameter of each hose is also different, and it needs to be installed according to the size requirements; 3.
    Under the load of the laboratory small refrigeration unit, the water output of the equipment should be kept stable; 4.
    The installation of the small laboratory refrigeration unit, the circulation pump The location should be accurately positioned according to the instructions to ensure the air supply effect of the generator; 5.
    If it is water-cooled, Wuxi Guanya recommends installing it in a place with good water quality to avoid scaling and heat transfer caused by water quality problems
    .

    Precautions for the use of small laboratory refrigeration units: 1.
    Pay attention to data such as intake, exhaust, oil pressure, and oil temperature
    .

    During the operation of the laboratory small refrigeration unit, check the accuracy of each instrument; 2.
    If the equipment stops due to reliable protection during operation, the operator should check the corresponding failure cause before starting the machine; 3.
    If it is If the shutdown caused by a sudden power failure, pay attention to whether it is reversed, and shut down quickly when it occurs; 4.
    If the small laboratory refrigeration unit is shut down for a long time, it is recommended to drain all the water in the equipment to avoid freezing the equipment in an excessively cold environment; 5 , If the equipment is started in the low temperature season, it is recommended to start the oil pump first and let the oil circulate in the equipment for a period of time
    .

    It is recommended to start the device manually
    .

    When using small laboratory refrigeration units, it is necessary to avoid problems caused by improper use of small laboratory refrigeration units
    .

     
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.