The pilot-scale refrigeration and heating integrated machine is a device that uses heat-conducting medium for fluid cooling and heating dynamic temperature control.
It is used in pharmaceutical, chemical, semiconductor and other industries to help customers complete process temperature control, and conduct heat-conducting medium or reaction material cooling and heating control
.
It is generally used in the pharmaceutical, chemical and laboratory industries to connect reaction kettles for refrigeration and heating reactions
.
1.
Regularly check whether the voltage and current are stable, and whether the compressor's running sound is normal.
During normal operation, the voltage is 380V and the current is within the range of 11-15, which is a normal phenomenon
.
2.
Regularly check whether there is leakage of refrigerant: refer to the parameters displayed on the high and low pressure meter on the front panel of the main unit to determine
.
Depending on the temperature (winter, summer) temperature changes, the device pressure display is also different
.
3.
Check whether the cooling system is normal, whether the cooling tower fan and sprinkler shaft work well, and whether the water supply of the built-in water tank is normal
.
4.
System cleaning should be done after six months of use.
The main cleaning parts include: cooling water tower, cooling water pipe and condenser part to ensure better cooling effect
.
5.
When not in use for a long time, the circuit switches such as the water pump, compressor and the main power supply of the cooling water tower should be turned off in time
.
During the normal operation of the pilot-scale refrigeration and heating integrated machine, it is inevitable that dirt or other impurities will affect the refrigeration effect
.
Therefore, in order to prolong the service life of the main unit and make the cooling effect reach the state, regular maintenance and maintenance work should be done to ensure the operation quality of the chiller and improve the production efficiency
.
The pilot-scale refrigeration and heating integrated machine needs to be connected with a cooling water tower and a circulating water pump to achieve the cooling effect.
In order to ensure the quality of the circulating water, a filter can be installed at the water source to prevent impurities from entering the pipeline and affecting the operation of the unit.
.
It is used in pharmaceutical, chemical, semiconductor and other industries to help customers complete process temperature control, and conduct heat-conducting medium or reaction material cooling and heating control
.
It is generally used in the pharmaceutical, chemical and laboratory industries to connect reaction kettles for refrigeration and heating reactions
.
1.
Regularly check whether the voltage and current are stable, and whether the compressor's running sound is normal.
During normal operation, the voltage is 380V and the current is within the range of 11-15, which is a normal phenomenon
.
2.
Regularly check whether there is leakage of refrigerant: refer to the parameters displayed on the high and low pressure meter on the front panel of the main unit to determine
.
Depending on the temperature (winter, summer) temperature changes, the device pressure display is also different
.
3.
Check whether the cooling system is normal, whether the cooling tower fan and sprinkler shaft work well, and whether the water supply of the built-in water tank is normal
.
4.
System cleaning should be done after six months of use.
The main cleaning parts include: cooling water tower, cooling water pipe and condenser part to ensure better cooling effect
.
5.
When not in use for a long time, the circuit switches such as the water pump, compressor and the main power supply of the cooling water tower should be turned off in time
.
During the normal operation of the pilot-scale refrigeration and heating integrated machine, it is inevitable that dirt or other impurities will affect the refrigeration effect
.
Therefore, in order to prolong the service life of the main unit and make the cooling effect reach the state, regular maintenance and maintenance work should be done to ensure the operation quality of the chiller and improve the production efficiency
.
The pilot-scale refrigeration and heating integrated machine needs to be connected with a cooling water tower and a circulating water pump to achieve the cooling effect.
In order to ensure the quality of the circulating water, a filter can be installed at the water source to prevent impurities from entering the pipeline and affecting the operation of the unit.
.