    Maintenance knowledge of chemical reactor heating and cooling integrated machine

    • Last Update: 2022-05-03
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    As a kind of industrial equipment, the Wuxi Guanya Chemical Reactor Heating and Refrigeration Integrated Machine has the possibility of failure.
    Now I will take you to understand that the compressor of the Chemical Reactor Heating and Refrigeration Integrated Machine suddenly stops.
    What should you do? 1.
    Sudden power failure causes the chemical reactor heating and cooling integrated machine to shut down.
    During the operation of the refrigeration compressor, if there is a sudden power failure, first disconnect the main power switch, immediately close the suction valve and discharge valve of the compressor, and then close the liquid supply gate valve, stop Supply liquid to the air conditioner evaporator to prevent the evaporator's humidity from shrinking due to excess liquid the next time the equipment is run
    .

    2.
    The heating and refrigeration integrated machine of the chemical reactor is stopped due to sudden water cut off.
    If the circulating water is suddenly cut off, the switching power supply should be cut off immediately, and the operation of the compressor should be stopped to prevent the working pressure of the refrigerator from being too high
    .

    After the air compressor is stopped, the suction and exhaust valves and related liquid supply valves should be closed immediately.
    After the cause is identified, the common faults should be eliminated, and the power supply should be repaired before restarting
    .

    3.
    Common failures of the compressor of the heating and cooling integrated machine of the chemical reactor.
    When the compressor is in urgent need of shutdown due to the destruction of a certain part of the compressor during operation, if conditions permit, it can be operated according to all normal shutdowns.
    In case of emergency, it must be disconnected Turn off the power supply of the motor, and then turn off the suction and exhaust valves and the liquid supply gate valve
    .

    If there is a common failure of the refrigeration compressor, the switching power supply of the production workshop should be disconnected before maintenance
    .

    The maintenance of the heating and cooling integrated machine of the chemical reaction kettle is a more important matter.
    To solve the common faults of the equipment, you must hire a technician, and there is a certain risk in solving it without authorization
    .

     
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.