-
Categories
-
Pharmaceutical Intermediates
-
Active Pharmaceutical Ingredients
-
Food Additives
- Industrial Coatings
- Agrochemicals
- Dyes and Pigments
- Surfactant
- Flavors and Fragrances
- Chemical Reagents
- Catalyst and Auxiliary
- Natural Products
- Inorganic Chemistry
-
Organic Chemistry
-
Biochemical Engineering
- Analytical Chemistry
-
Cosmetic Ingredient
- Water Treatment Chemical
-
Pharmaceutical Intermediates
Promotion
ECHEMI Mall
Wholesale
Weekly Price
Exhibition
News
-
Trade Service
Laser Headspace Analyzer Pharmaceutical Leak Detection Standard Recognized High Accuracy Japan Import Model: LS-07 Wavelength: 763 nm Detection: Oxygen (%)LS-14 Wavelength: 1,382 nm Detection: Water Vapor (mg/L, Torr), Pressure (Torr)LS-21 Wavelength: 763 nm Detection: Oxygen (%) (Dual Detection Unit) Wavelength: 1,382 nm Detection: Water Vapor (mg/L, Torr), Pressure (Torr) Features: High Sensitivity: 0.
1 um Leak Detection Detection sensitivity ·· Rapid detection: A few seconds of detection time (using 10 injection brackets, rapid detection)·· Completely non-destructive testing method: The test process is completely non-destructive to the packaging container and the sample ·· No nitrogen purge required: No nitrogen purge of the cavity is required during the test ·· No need to customize the chamber per specification: Multi-gauge measuring vessel size size by adjusting the height and width of the measuring probe: 1-20ml, φ12-30 mm * Larger or smaller size adjustable for a group of samples 10 pieces, 97 seconds to complete the test rate: * Single test speed of 5 seconds Typical single test speed is: 9 seconds measurement time: 1–5 seconds to use operation: Run offline automatic injection test accessories: Each specification is configured with injection bracket drive mode: Single-axis drive test probe: oxygen and water vapor, Pressure Separate Test Cell, or Simultaneous Installation of Two Test Units Test Probes Height and Width Adjustable for Sample Rotating Chassis of Different Sizes: Chassis 360 at the Time of Measurement.
Rotating Pharmaceutical Leak Detection Standard Approved High Precision Laser Headspace Analyzer Physical and Electrical Supply Power Supply 100 VAC Nitrogen Purge Without Nitrogen Purge, (Optional Nitrogen Purge ) Compressed Air Without Compressed Air Operation Button Test, Emergency Stop, Nitrogen Purge ON/OFF, Detection Unit Height Width Adjustment Control Panel 10 inch Display / Windows 10 System / System Settings / Run Actions / Alarm Prompts