    Home > Coatings News > Paints and Coatings Market > Jiangsu issued the chemical industry safety and environmental protection and refinement requirements! 10 types of closure exit, 11 types of shutdown rectification, 11 categories of deadline rectification

    Jiangsu issued the chemical industry safety and environmental protection and refinement requirements! 10 types of closure exit, 11 types of shutdown rectification, 11 categories of deadline rectification

    • Last Update: 2019-06-12
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com

    recently, Jiangsu Province chemical industry safety and environmental protection promotion leading group office issued a notice on the issuance of chemical industry safety and environmental protection improvement work related to the detailed requirementsin the annex "Jiangsu Province chemical industry safety rectification and upgrading work refinement requirements" clearly put forward the closure of the exit category (10), stop-stop rectification class (11) and the deadline for rectification class (11), in which the closure and exit class mentioned that the evaluation and confirmation of the chemical concentration area, the production and use of chemical production enterprises or production devices with explosive properties16 chemicals, including epoxy chloropropane and propane oxide, are included in the list of chemicals with explosive properties listed at the back of the documentThis means that in all assessed chemical concentration areas in Jiangsu Province, will the production and use of the above-mentioned explosive chemicals be shut down and exited?the specific refinement requirements are as follows:(i) close exit class (10)1included in the obsolete obsolete catalog of products, technology, technology and equipment2Engage in the production and operation of hazardous chemicals without obtaining a safe production, use or business license in accordance with the law; and the construction of hazardous chemicals construction projects or installations in service have failed to pass the safety conditions, safety facilities design review and inspection and acceptance of safety facilities3Chemical production equipment has been parked for more than one year and there are uncontrollable safety problems in the restart of the plant4Chemical production enterprises that have been determined by the fire department to be a major fire hazard and cannot complete rectification5Chemical production and use of chemical production enterprises or production plants with explosive properties in the chemical concentration area assessed and confirmed6 A total of more than 3 major accidents of production safety or serious administrative penalties have been imposed within twelve consecutive months 7 Chemical production enterprises or production devices that fail to carry out essential safety diagnostic management or cannot complete rectification by essential safety diagnosis and treatment according to the provisions 8 Highly toxic, flammable and explosive chemical production enterprises that do not have safe production conditions 9 Chemical production enterprises that constitute a major hazard source of a class I and II hazardous chemicals and a safety distance between important public buildings that do not meet the relevant national standards 10 Chemical production enterprises that still do not have the conditions for safe production after discontinuation and rectification (2) Discontinued rectification category (11 1 The device involved in the supervision of hazardous chemical processes has not been automated control, the system has not realized the emergency parking function, and the automatic control system and emergency parking system of equipment have not been put into use 2 The hazardous chemical storage tank area has not set up the tank high and low level alarm in accordance with the relevant provisions, and has not used the super-high level automatic interlocking to close the tank feed valve and ultra-low level automatic interlocking to stop the material transport measures; 3 The control room or cabinet facing the side of the fire or explosion hazard device does not meet the requirements of national standards for fire prevention and explosion prevention; the production device involving the nitrogen hazard chemical process does not have a regional control room or central control room; 4 The places involved in flammable and toxic and hazardous gas leakage have not set up detection alarm devices in accordance with national standards, the alarm signals are not sent to the control room or operating room, and the explosive hazardous sites are not installed and used explosion-proof electrical equipment in accordance with national standards 5 The distance between fire prevention and external safety protection and external safety protection between enterprises and surrounding residential areas and important public buildings, railways and highways does not conform to the requirements of laws, regulations, standards and norms 6 The source of the process technology is unknown and cannot provide proof of the safety and reliability of the process, the chemical technology used for the first time in China has not been verified by the safety and reliability of the relevant departments of the provincial people's government, and the newly developed production process of hazardous chemicals has been directly industrialized without minor, pilot and industrialization tests 7 The site that may cause fire and explosion on the process device is not equipped with such detection instruments, sound and light alarm and safety interlocking devices such as overtemperature and overpressure 8 By the end of 2019, enterprises have not established an integrated information management system such as monitoring information of major hazard sources, detection and alarm information of flammable toxic gas, partition information of enterprise security risk, information of production personnel on duty and management information of the whole process of production 9 The enterprise has not formulated the work system for the investigation and commitment of security risks, has not appointed a person to be responsible for the work of risk security risk investigation, has not established an institutional system of security risk investigation and risk control of the whole enterprise, full post and whole process, and has not set up a special section to publicize the contents of the enterprise security commitment announcement 10 The filling of flammable and explosive, toxic and harmful liquefied gases such as liquefied hydrocarbons, liquid ammonia and liquid chlorine is not equipped with a universal pipe filling system 11 The spherical tanks of propylene, propane, mixed carbon iv, pumped carbon iv and liquefied petroleum gas, and the full-pressure liquefied hydrocarbon storage tanks did not set water injection measures according to national standards (3) time-limited rectification category (11)
    1 The actual controller does not act as a legal representative; the principal person in charge does not have more than 3 years of experience in the chemical industry or does not have a college degree or above The principal person in charge of chemical enterprises, in charge of safety and production, none of the persons in charge of safety and production, not a person with a national education and chemical professional university degree or above, or with the chemical professional senior engineer technical titles; 2 The principal person in charge of chemical enterprises, technical persons in charge, safety persons in charge and full-time safety management personnel shall pass the examination without the training of their ability to practice; 3 The operators engaged in hazardous work posts have not met the basic conditions for their employment; the special operations personnel have not qualified for the special operation operation without the qualification of their ability to practice; and the personnel engaged in special equipment operation and management have not obtained the qualification certificate of the corresponding special equipment operators 4 The number of full-time safety production management personnel is less than 2% of the total number of employees in Jiangsu Province Less than 15% of full-time safety management personnel are equipped with registered safety engineers (at least 1 person is equipped with less than 7 full-time safety managers) 5 The responsibility system for safe production covering all departments and personnel has not been established, and the rules and regulations and operating procedures for safe production have not been formulated and revised in a timely manner 6 Chemical production enterprises involved in major sources of hazardous chemicals, hazardous chemical processes or production, and the use of chemicals with explosive properties have not achieved secondary standardization 7 Highly toxic gases such as photogas and chlorine gas and hydrogen sulfide gas pipelines are involved in the passage of public areas outside the plant (including chemical parks and industrial parks) 8 Regional overhead power lines cross the production area and do not meet the requirements of national standards 9 Emergency relief materials are equipped without meeting the Requirements for Emergency Relief Materials for Hazardous Chemical Sons Units 10 Fine chemical enterprises did not carry out a reaction safety risk assessment as required by the normative document 11 Chemical production equipment does not set up dual power supply according to national standards, and the automatic control system does not set up uninterruptible power supply nouns explained (i) chemicals with explosive properties refer to ethylene oxide, oxypropane, oxycodone, peroxyteiathane, peroxide, methylacetate, peroxide (d) benzoyl, nitrouprecyllifctifctifctifadin, nitroucellulose, nitric acid, 16 chemicals, such as paraben oxide, nitrosamine, N, N'-ditinitro-ditrite pentamethyltetramine, 2,2'-disainant dibutyl, dinitrogly tithyl, nitrogistrium, nitrobenzene, ammonium nitrate, etc (2) Major administrative punishment refers to the administrative punishment of an enterprise that has ordered the enterprise to stop production and rectify, order it to stop production and stop work, order it to stop construction, order it to stop construction, revoke the relevant license, revoke the relevant license or post certificate, fine more than 50,000 yuan, confiscate illegally mined coal products, confiscate illegally mined coal products or extractive equipment worth more than 50,000 yuan (3) The actual controller of the means a person who is not a shareholder of the company but who can actually control the company's behavior through investment relations, agreements or other arrangements (4) The overhead power line in the area of overhead power lines in the area refers to overhead power lines with a voltage level of more than 35kV
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.