    Infusion device leakage positive and negative pressure tester technical parameters

    • Last Update: 2022-09-08
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    Infusions are the most common treatment in China, with studies showing that more than 5 billion disposable infusion sets are used in China each year
    .

    Are these infusion sets really safe? In 2017, 43,500 adverse events reported by disposable infusion devices were reported nationwide, accounting for 11.
    57% of the total, making it the most problematic medical device
    in China.

    Therefore, the infusion device inspection link is indispensable, how to test the positive pressure and negative pressure of the infusion device leakage? ——Infusion infusion leak positive and negative pressure tester SZF8368-C infusion device leakage positive and negative pressure tester technical indicators programmable controller: PLC/ARM Chinese and English window display, 7.
    0 inch 800×480 graphic dot matrix K600 + core 65K color DGUS screen, using graphic keyboard to control the menu on the LCD screen and the analog keyboard on the touch display
    .

    SZF8368-C infusion infusion device leakage positive and negative pressure tester detection process: (1) mounting fixture (2) turn on the power supply (3) set parameters (pressure value and hold time parameters); Positive pressure output range: higher than the local atmospheric pressure, 1kPa ~ 150 kPa, the pressure output value can be set arbitrarily, and the verification error is not greater than ±1% of the reading; Negative pressure output range: lower than the local atmospheric pressure, 0kPa ~ -60 kPa, the pressure output value can be set arbitrarily, and the verification error is not greater than ±1%
    of the reading.

    The duration of the positive pressure and negative pressure test: 0.
    1 seconds to 99.
    9 minutes, the error is not greater than ±0.
    1S
    .

    (4) One-click test, click "Infusion leak positive and negative pressure test"
    .

    (5) Print the report
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.