    The chemical high and low temperature circulation device can heat or cool the materials in the reactor at a constant temperature through the interlayer of the reactor, and can provide stirring
    .

    The materials are reacted in the reactor, which is widely used in chemical, biopharmaceutical and other industries
    .


    In order to reduce the energy consumption of chemical high and low temperature cycle devices, we must first provide a good operating environment
    .

    For example, the voltage in the power environment is low, and in order to maintain stable operating efficiency, the equipment will inevitably increase the power consumption
    .

    And the voltage is too high will also cause the chemical high and low temperature cycle device failure and other problems
    .

    If you want to control the efficiency of chemical high and low temperature cycle devices and maintain the reliability and stability of the system, you must formulate a specific use plan.
    No matter what kind of equipment, if there is no clear plan, the system will be overloaded, which will seriously affect the product.
    quality
    .

    Regular maintenance of chemical high and low temperature circulation devices can ensure the stability of the equipment.
    No matter if any equipment lacks maintenance and maintenance, some efficiency will be reduced
    .

    Naturally, this maintenance is purposeful, for example, it can start from the system
    .

    Only when the maintenance work is done, the equipment can be used better and the efficiency will be greatly improved
    .

      Because the chemical high and low temperature circulation device is greatly affected by the environment, while ensuring the quality, we must also pay attention to the environmental impact of the equipment, and must not affect the environment when using it
    .

    In order to make it meet the requirements of use, the condensing temperature must be lowered to make it more efficient
    .

      When running, the longer the run time, the greater the energy consumption
    .

    A regulating coil can be installed on the chemical high and low temperature circulation device to adjust the appropriate operating power according to the ambient temperature, such as cooling the equipment within a certain operating power range
    .

    The energy consumption is equivalent to the operating power.
    Mastering the method of adjusting the operating power of the chemical high and low temperature cycle device can control the operating power under the premise of meeting the operating requirements of the enterprise
    .

      1.
    When working or at the end, it is strictly forbidden to disassemble under pressure, and it is strictly forbidden to work the kettle under the condition of overpressure and overtemperature
    .

      2.
    Be careful not to add water or other liquids when adding heat transfer oil, and check the oil level of the heat transfer oil from time to time
    .

      3.
    If there is abnormal sound inside the isolation sleeve during operation, stop the machine to release the pressure and check whether there is any abnormality in the stirring system
    .

    Regularly check the swing amount of the stirring shaft.
    If the swing amount is too large, the bearing or sliding sleeve should be replaced in time
    .

      4.
    The voltage used is connected to the corresponding voltage.
    In order to ensure the normal operation of the equipment, the grounding wire must be connected, and the flammable and explosive environment such as oil and gas should be avoided
    .

      5.
    When the reaction temperature is determined, it is not allowed to change the temperature setting value during the heating process, so as to avoid a large overshoot of the temperature
    .


    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.