    How to maintain the high and low temperature impact test chamber after the experiment, when it comes to maintenance, it should be a question that many people want to know! To know what the software of the machine equipment experiment system is, it is very important to have an immediate response to the operating characteristics of the refrigeration compressor.
    relationship
    .

    The refrigeration unit is a key component of the temperature tester, and the maintenance of the refrigeration compressor is even more critical
    .

    Next, Aipei Technology will summarize some experience and experience for you! 1.
    Because the refrigeration compressor has a gas breathing system, if there is a lot of dust in the surrounding environment of the machine and equipment, a filter system should be added.
    In addition, the gas is not allowed to contain flammable and Corrosive gas, to prevent explosion or internal rust
    .

    In general, make sure that the air humidity of the gas is low, very small, and that natural ventilation is good
    .

    2.
    The reduced characteristics are not suitable for high temperature, and the working temperature is less than 30 °C
    .

    If the temperature is too high, the output air volume of the refrigeration compressor will be reduced
    .

    3.
    The machinery and equipment should be placed in a wide area.
    The narrow indoor space is not conducive to the maintenance and maintenance in the middle and later stages.
    Especially the heat pipe radiator (cooler) of the refrigerator of the refrigeration compressor should be maintained on time and kept clean
    .

       4.
    The working voltage of the working environment of the environmental test chamber should be maintained for a long time.
    Otherwise, the current will be too large or too small.
    Frequently summing up under this standard will cause the refrigeration compressor to be damaged
    .

       5.
    The environmental test box should be built on a hard plastic floor, and the basic plan must be leveled before installation to prevent the refrigeration compressor from causing vibration and noise
    .

       6.
    In the whole process of the experiment, it is not suitable to start the refrigeration compressor frequently, and the time interval for starting the refrigeration compressor is 15 minutes
    .

       7.
    When the equipment is in trial operation, strictly check the running position of the refrigeration compressor.
    When it is found that it is turned over, it should be turned off first, disconnect the switching power supply, exchange all two three-phase wires and start it again, otherwise the refrigeration compressor will be damaged.

    .

       8.
    During the work of the experimental equipment, regularly check the maintenance system software such as refrigeration compressor valves to ensure its dexterity and reliability
    .

     
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.