    Home > Active Ingredient News > Drugs Articles > How to maintain the capsule filling machine?

    How to maintain the capsule filling machine?

    • Last Update: 2022-09-14
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    Cleaning parts 1, when the normal working time of the machine is long, it is necessary to regularly clean up the direct contact with the drug, and when the batch of drugs is replaced or the discontinuation time is longer, it is also necessary to clean up
    .

    Add lubricating oil 2, the transmission mechanism under the machine work surface should often add lubricating oil (grease) in an appropriate amount to reduce the wear
    of moving parts.

    Check the amount of oil 3, the main transmission reducer should check the amount of oil once a month, when insufficient, it should be refueled in time, and the lubricating oil should be replaced once every six months; The turntable station indexing box should be replaced once every 3000h, and 90# engine oil
    is generally used according to experience.

    Safety clutch 4, safety clutch is the machine overload when the protective role, the load is normal when the clutch should not be slipped, but due to long-term use may also appear slippage phenomenon, when the normal use of the phenomenon of slippage, you can tighten the clutch of the round nut, in order to ensure the normal operation of the machine can also play a protective role
    .

    Vacuum separator 5, vacuum system vacuum separator in the filling of the hard capsule mainly plays a role in the capsule into the upper and lower modules and the cap, the body separation, if the capsule can not cap, body separation, the subsequent filling will not be able to carry out
    .

    The turntable of the machine rotates for every station, the spindle of the machine rotates for 1 week, and the vacuum separator moves up and down once
    under the action of the cam.

    If the capsule cap and body separation are not smooth, the gap between the upper plane of the vacuum separator and the lower plane of the lower module should be checked, and the gap is too large so that the vacuum degree of the vacuum system cannot reach the vacuum required by the cap and body separation (about 0.
    05MPa), and the gap is too small and easy to cause a collision to deform
    the lower module.

    When the position of the vacuum separator needs to be adjusted, turn the main motor shaft with the handle to make the vacuum separator rise to the zui high position, loosen the lock nuts at both ends of the adjustment rod under the machine table (one is a left-handed nut, one is a right-handed nut), and then rotate the adjustment lever to adjust the height of the vacuum separator, and then lock the nut, and turn the spindle shaft with the handle until it is
    suitable.

    The vacuum degree is read out on the vacuum gauge of the machine operation panel, and the vacuum control valve can be opened appropriately when the vacuum is too high, and the vacuum control valve
    can be closed or closed when the vacuum is too low.

    The filter of the vacuum system should be opened regularly to remove the clogged dirt to ensure that the vacuum system has sufficient vacuum
    .

    Transmission chain 6, the transmission chain should be checked once a week, and add an appropriate amount of grease, if necessary, it needs to be tightened
    again.

    When the chain is too loose and needs to be tightened again, the tensioning wheel should be moved to adjust, but the chain cannot be opened or the chain cannot be taken off the sprocket, so as not to disrupt the movement order of the entire mechanism and prevent the interference
    of the movement of the mechanism.

     
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.