Cleaning parts 1, when the normal working time of the machine is long, it is necessary to regularly clean up the direct contact with the drug, and when the batch of drugs is replaced or the discontinuation time is longer, it is also necessary to clean up
.
Add lubricating oil 2, the transmission mechanism under the machine work surface should often add lubricating oil (grease) in an appropriate amount to reduce the wear
of moving parts.
Check the amount of oil 3, the main transmission reducer should check the amount of oil once a month, when insufficient, it should be refueled in time, and the lubricating oil should be replaced once every six months; The turntable station indexing box should be replaced once every 3000h, and 90# engine oil
is generally used according to experience.
Safety clutch 4, safety clutch is the machine overload when the protective role, the load is normal when the clutch should not be slipped, but due to long-term use may also appear slippage phenomenon, when the normal use of the phenomenon of slippage, you can tighten the clutch of the round nut, in order to ensure the normal operation of the machine can also play a protective role
.
Vacuum separator 5, vacuum system vacuum separator in the filling of the hard capsule mainly plays a role in the capsule into the upper and lower modules and the cap, the body separation, if the capsule can not cap, body separation, the subsequent filling will not be able to carry out
.
The turntable of the machine rotates for every station, the spindle of the machine rotates for 1 week, and the vacuum separator moves up and down once
under the action of the cam.
If the capsule cap and body separation are not smooth, the gap between the upper plane of the vacuum separator and the lower plane of the lower module should be checked, and the gap is too large so that the vacuum degree of the vacuum system cannot reach the vacuum required by the cap and body separation (about 0.
05MPa), and the gap is too small and easy to cause a collision to deform
the lower module.
When the position of the vacuum separator needs to be adjusted, turn the main motor shaft with the handle to make the vacuum separator rise to the zui high position, loosen the lock nuts at both ends of the adjustment rod under the machine table (one is a left-handed nut, one is a right-handed nut), and then rotate the adjustment lever to adjust the height of the vacuum separator, and then lock the nut, and turn the spindle shaft with the handle until it is
suitable.
The vacuum degree is read out on the vacuum gauge of the machine operation panel, and the vacuum control valve can be opened appropriately when the vacuum is too high, and the vacuum control valve
can be closed or closed when the vacuum is too low.
The filter of the vacuum system should be opened regularly to remove the clogged dirt to ensure that the vacuum system has sufficient vacuum
.
Transmission chain 6, the transmission chain should be checked once a week, and add an appropriate amount of grease, if necessary, it needs to be tightened
again.
When the chain is too loose and needs to be tightened again, the tensioning wheel should be moved to adjust, but the chain cannot be opened or the chain cannot be taken off the sprocket, so as not to disrupt the movement order of the entire mechanism and prevent the interference
of the movement of the mechanism.