The integrated pharmaceutical refrigeration and heating cycle machine can heat or cool the materials in the reactor at a constant temperature through the interlayer of the reactor, and can provide stirring
.
The materials are reacted in the reactor, which is widely used in chemical, biopharmaceutical and other industries
.
1.
Regularly clean the evaporator: due to the different degrees of cleanliness in the experiment, a large amount of dust and other small particles will accumulate under the strong wind cycle, which should be cleaned regularly
.
2.
The condenser should be cleaned every 3 months.
For air-cooled compressors, the condensing fan should be regularly maintained, and the condenser should be dedusted and decontaminated to ensure its ventilation and heat exchange
.
For water-cooled compressors, it is necessary not only to ensure the water supply pressure and temperature, but also to ensure the corresponding flow, and to regularly clean and descale the condenser to obtain continuous heat exchange performance
.
3.
Due to different working environments, a large amount of dust and other small particles will accumulate on the circulating fan blades and the condenser fan, which should be cleaned regularly
.
4.
After each experiment, set the temperature to a position close to the ambient temperature.
After working for about 30 minutes, turn off the power and wipe the inner wall of the studio
.
5.
When it is not in use for a long time, the equipment should be energized every half month according to the regulations, and the energization time should be more than 1 hour
.
6.
Do not start and stop the switch button frequently during use, and assign special personnel to operate and maintain it
.
The flow rate of the integrated pharmaceutical refrigeration and heating cycle machine can be adjusted and customized.
According to the user's requirements, the low temperature and the cooling capacity, and the low temperature and the container capacity are reasonably matched, which can meet the actual needs of users in different industries
.