The automatic control system of the reactor is a commonly used temperature control equipment in the industry, in the refrigeration and heating process, the temperature change in the temperature control device is realized through the reciprocating cycle of the medium or refrigerant, so as to achieve the effect
of refrigeration and heating.
1.
The automatic control system of the reactor has automatic temperature sensing function
.
The controller adjusts according to the detected temperature and the set temperature value to achieve the purpose of controlling the
temperature.
The entire process of detection and adjustment is automatically controlled and the integrated device is easy to use
.
2.
Pressure control is generally composed
of high pressure control part and low pressure control part.
When the exhaust pressure exceeds a certain value, the compressor's high-pressure control will cut off the power supply of the compressor, and when the pressure value is lower than a certain value, the low-pressure control will also cut off the compressor's power supply and issue an alarm signal
.
3.
In order to prevent the compressor from failing during high load operation, the installation of overheating relays can effectively ensure the overload
of the compressor.
Conventional three-phase motors are missing phases and can cause the motor to fail to start or be overloaded, and overload relays can be used to avoid damage
to the motor due to lack of phase.
4.
There is a temperature control system
at the exhaust port.
When the exhaust temperature is too high, the temperature control system automatically cuts off the circuit
.
Excessive temperature in the equipment housing can also affect the compressor
.
The main reason is that due to the insufficient heat exchange power of the condenser, it is necessary to check its state to see whether its air volume, water volume, and water temperature are normal, and check whether there is air entry or other stains
in the equipment unit.