TCU multiple reactor temperature control maintenance is indispensable in the mechanical equipment, only regular maintenance of the machine, the machine will not appear aging or not working, not only can make the usual work efficiency improve, but also can make the equipment life extended, reduce the operational danger, so that the equipment can be more durable
.
1, the protection device setting manufacturer has been set, the user should not change it at will when using
.
2.
Regularly check whether the heat dissipation system is normal, whether the cooling tower fan and sprinkler shaft are running well, and whether the water replenishment of the built-in water tank is normal
.
Regularly check whether the refrigerant controlled by the temperature control of multiple reactors in the TCU has leaks: it can be determined
by referring to the parameters displayed by the high and low pressure gauges of the front panel of the host.
3.
When the TCU multiple reactor temperature control units have a fault alarm shutdown, they should first press the alarm shutdown button, and then check the cause of the failure, and remember not to force the operation before troubleshooting
.
4.
If there is no emergency when the temperature control of multiple reactors in the TCU is used, do not shut down the unit by cutting off the power supply; If the unit is stopped in use for a long time in winter, the unit is shut down first, and then the main power supply is turned off to drain
the water in the machine.
5, the use of TCU multiple reactor temperature control to keep the machine room clean, good ventilation, to regularly clean the condenser to ensure the normal operation of
the unit.
6, but also to ensure a good heat dissipation effect, which should keep the surface of the heat dissipation coil clean, to ensure that the air circulation around the machine, low temperature, and regular cleaning of the heat dissipation coil
.
7.
Clean once a year, the main cleaning parts include: cooling water tower, loose water pipe pipe and condenser part to ensure better
cooling effect.