    How should I properly solve the problem of handling water leakage in the salt spray test chamber?

    • Last Update: 2022-10-03
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    For the water leakage of the salt spray test chamber, the possible causes
    of water leakage are analyzed in detail below.

    The analysis of salt spray test chambers has a total of three places to use water
    during use.

    First there is the test chamber, then the salt water for spraying, and finally the saturated air bucket to use the water
    .

    After a long period of continuous use, when the equipment is found to be leaking, it is necessary to observe more, in order to carry out the "right medicine" according to the specific situation to ensure the effect of "disease elimination"! First, observe the location of the leakage in which direction of the salt spray box, left front, left back or right front, right rear? The distribution circuit of the salt spray tester is usually on the right side of the salt spray box, if the water leaks on the right side, the control board should be opened, all electrical fittings, gas pipe joints, saturated air barrels are in the control box, and it should not be difficult
    to find the location of the leakage.

    Here, you can check
    one by one.

    Can you first check whether the trachea and water pipe are aging and broken? Are the individual pneumatic joints aging? Is the welded part of the saturated air bucket rusty? Is the spray regulator leaking air and water? If the equipment has been used for more than 3 years, there are various possibilities, and it should not be difficult to find the location of
    the water leak as long as these items are carefully observed.

    Second, if it is a leakage in the back of the salt spray test box, it is necessary to check whether the drainage pipe behind is connected, and the salt spray tester of more than 90 specifications has an overflow port in the box, and the water will automatically flow to the outside of the box, so a drainage pipe must be connected to the sewer or outdoor
    .

    Otherwise, place a small water tank at the drainage port of the salt spray meter, and do not let the water flow all
    over the ground.

    Third, check whether the valves of the salt spray test chamber are leaking? After the equipment has been used for a long time, just like the valve of the pressure bucket manual water outlet, after frequent use, the valve will not be able to close the water, so it is necessary to consider installing another valve on the original valve
    .

    Fourth, for the leakage of some parts, you can use high temperature sealant to treat, buy transparent glue effect is very good! If it is a leak in the sealed sink, it is necessary to use a welding gun for reinforcement, and if it is a leakage of salt water in the entrance of the drug, it is necessary to use PVC glue to reinforce
    .

    For stainless steel saturated air bucket leakage, if the salt water is accidentally added in, it is necessary to replace the pressure barrel, which is useless
    for rewelding.

    Fifth, in daily operation, often pay attention to observe whether there is a leakage of water, electricity, gas leakage? Problems are found to be dealt with in time, can not be delayed, to avoid causing circuit short circuit failure
    .

    Every 3 to 4 years, replace all aging tracheas and water pipes just in case!
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.