German BECKHOFF EK1100 EtherCAT coupler parameter data EK1100 EtherCAT coupler is a link
between the fieldbus level EtherCAT protocol and the EtherCAT terminal module.
The coupler converts the passed message from Ethernet 100BASE-TX to an E-bus signal representation
.
A station consists of a coupler and any number of EtherCAT terminal modules, which are automatically detected and displayed individually in the
process image.
BECKHOFF EK1100 EtherCAT coupler data special features: Connection technology: 2 x RJ45 Socket connection length: up to 100 m Number of EtherCAT terminal modules in the entire system: up to 65,535 EK1100 There are two RJ45 sockets
.
The upper Ethernet interface is used to connect the coupler to the network; The lower socket is used for optional connection to other EtherCAT devices
in the same network segment.
In addition, EtherCAT connectors or EtherCAT extensions can be used to extend or set up linear or star topologies
.
Both system and field power are 24 V DC and are provided
directly on the coupler.
The connected EtherCAT terminal module provides the current
required for communication from the supplied system voltage.
The coupler is available up to 5 V and 2 A
.
If higher currents are required, power terminals
such as the EL9410 must be integrated.
Field power is delivered to individual I/O components
via power contacts up to 10 A.
In an EtherCAT network, the EK1100 can be installed anywhere in the Ethernet signaling section (100BASE-TX) – except directly on the
switch.
The EK9000 and EK1000 couplers are available for switches
.
Technical dataCoupling data transmission medium EtherCAT terminal module (ELxxxx) in the EK1100EtherCAT system and 100BASE-TX EtherCAT network (low Cat.
5) with maximum
distance between shielded stations 。 100 m (100BASE-TX)EtherCAT Number of terminals up to 65,534ProtocolEtherCAT delay approx.
1 microsecond data transfer rate100 megabits/s bus interface2 RJ45 power supply24 VDC (-15 %/+20 %)US current consumption70 mA + (∑ E-bus current/4)Current consumption from U PLoad current supply E-bus2000 mA power supply contacts maximum
。 24 V DC/max.
10 A galvanically isolated 500 V (power contact/supply voltage/Ethernet) operating/storing temperature -25.
.
.
+60 °C/-40.
.
.
+85 °CEMC immunity/radiation according to EN 61000-6-2/EN 61000-6-4 relative humidity 95 %, non-condensing vibration/shock resistant according to EN 60068-2-6/EN 60068-2-27 protection
。 Rating/Installation PositionIP20/Variable Approval/Marking CE, UL, ATEX, DNV GL, IECEx, cFMus Ex mark ATEX: II 3 G Ex nA IIC T4 GcIECEx: Ex nA IIC T4 GcEx tc IIIC T135 °C DccFMus: Class I, Division 2, Groups A, B, C, DClass I, Zone 2, AEx ec IIC T4 GC Housing Data EK-44-8pin Design Form Compact Terminal Housing Material with Signal LED Polycarbonate Size (W x H x D) 44 mm x 100 mm x 68 mm mounted on a 35 mm DIN rail in accordance with EN 60715 Label wiring solid conductor (e), flexible conductor (f) and ferrule (a) with lock by side-by-side installation double slot and key connection marking BZxxx series Solid conductor (e), flexible conductor (f) and ferrule (a): screwdriver driven spring connection section s*: 0.
08.
.
.
2.
5 mm²,st*: 0.
08.
.
.
2.
5 mm²,f*: 0.
14.
.
.
1.
5 mm² connection cross-section AWGs*: AWG 28.
.
.
14,st*:AWG 28.
.
.
14,f*:AWG 26.
.
.
16 stripping length 8.
.
.