    Ren Yunye (Jiangsu Ankerui Microgrid Research Institute Co.
    , Ltd.
    , Jiangsu Jiangyin 214405) Abstract: In recent years, China's scientific and technological level has been improved, so that modern communication technology has also continued to grow and develop, in this situation, the data center for power and environmental status monitoring needs are constantly improving
    .

    Whether the operation and maintenance staff of the data center can effectively control the operation of all points often has a huge impact on
    the stable operation of the data center.

    Data center power and environment monitoring system can supervise the power parameters and the status of the environment, unified collection and processing of real-time data, and in the first time the fault situation is reported, the system operation and alarm information for detailed records, to assist the computer room management personnel to conduct a comprehensive analysis of the operation of data center equipment, for each computer room environment hidden risks to judge
    .

    Keywords: data center; Power and environmental monitoring systems; 0 Introduction Driven by the rapid development of data business, the comprehensive functions of mathematical equipment and storage devices are also expanding, and the overall scale is gradually increasing, in order to ensure that the equipment can continue to maintain a stable state of operation, it is also necessary to pay attention to the implementation of equipment maintenance and management work to ensure that the data system can operate
    stably and safely.

    The formation of the centralized monitoring and management system of the power environment of the machine room can be said to be the inevitable development of society, which has the function of monitoring the operating state of the equipment, predicting the possible development of the fault, and solving it in a short period of time when encountering the fault, and also has the important functions of comprehensive management and unified regulation, so we need to continuously improve the operational stability of the power equipment to ensure the efficiency and effect of the operation of the data system, so as to effectively reduce the maintenance workload of personnel.
    Improve the efficiency
    of equipment operation.

    1 Data center power and environmental monitoring system (1) System composition combined with the current national implementation of the relevant policies, the current environmental monitoring system used in the three-level cascade of basic hardware structure is usually composed of data management, display, collection and monitoring branch equipment combination
    .

    The monitoring object mainly involves power distribution equipment, power supply, temperature and humidity, fire protection, electronic access control and other infrastructure
    .

    Management functions typically include fault prediction management, comprehensive performance management, configuration management, security management, and so on[1].


    The system shares the communication information of each branch system by means of computer database, communication, network sensors and other technologies, so as to ensure that the overall compatibility and scalability of the system can be fully exerted
    .

    (2) The system is deployed in those relatively large-scale data center computer rooms, and the three-level monitoring equipment, second-level monitoring equipment and terminal monitoring sensing equipment are installed, and the second-level monitoring equipment and terminal monitoring sensors
    are installed for the small-scale site data computer room.

    (C) the main features of the data center computer room power and environmental monitoring system monitoring system usually has the following functions: first of all, the real-time monitoring of the computer room can be implemented, and the images obtained by monitoring are saved by digital video recording, which is convenient
    for subsequent investigation and consultation.

    Secondly, it can be connected and coordinated with the existing access control management system in the computer room, and the seamless integration of the access control system can also be completed, so that the identity of the personnel entering and leaving the computer room can be checked and recorded, and the management efficiency and effect
    of the computer room can be improved.

    In addition, the use of audio and video surveillance can ensure that the computer room management personnel can check the situation of the computer room equipment and the computer room staff anytime and anywhere, and can also use the monitoring system to conduct video calls, which can also enhance the interaction while improving the monitoring work of the
    computer room.

    In addition, the environmental testing equipment set up in the system can timely supervise
    the start-up adjustment system, lightning protection detection system, fresh air system, water leakage detection and machine room temperature and humidity installed in the machine room.

    If the system releases a warning signal during the monitoring process, the alarm information can be formed immediately and the linkage function
    of the early warning equipment can be turned on within the specified range.

    In addition, it can be connected with the power distribution equipment in the computer room, and the duty management staff of the computer room can supervise and inspect the power configuration and the operation of each facility in the machine room with the help of the environmental monitoring system [2].


    The management platform of the monitoring system has a strong user-friendliness, the operation is very convenient, and it also has the functions of
    language prompts and Chinese character support.

    When the alarm information is issued, the alarm signal will also appear in the performance effect of sound and optoelectronics, using e-mail, mobile phone short message to remind the staff, combined with the warning information can accurately determine
    the location of the fault.

    2 system requirements (1) real-time accuracy dynamic ring monitoring system is the direct manifestation of the basic environmental state of the data center, and the accuracy and timeliness of its data are very important
    .

    Usually in the construction process, it is necessary to carry out regular inspections of the system, and the real-time data is passed to the monitoring terminal for display, and it is also necessary to use the warning method to provide timely and accurate data for the maintenance staff, and the data can also be compared with the historical record for analysis, so as to effectively prevent the occurrence
    of system failure.

    (2) Scalability is comprehensively considered for many aspects such as fluctuations in the actual needs of construction, and the monitoring system also needs to have the performance of receiving people to expand [3].


    First of all, expand the scope of monitoring, such as: when carrying out renovation work for some projects, monitoring and acquisition data systems or large-scale monitoring systems should be added on the basis of existing systems
    .

    Second, improve the level
    of monitoring work.

    In order to promote the improvement of the management level and bring a good practical experience to users, the general monitoring window of the control status situation should be added to the existing monitoring interface, so that the system can also be supervised and controlled
    by the system operation communication state.

    (3) When implementing the data center construction work, security needs to use the deployment of complete intelligent monitoring methods to supervise
    the computer room.

    For example, when carrying out system construction work, it is usually necessary to ensure that it has fire control measures and access control fading to give you linkage control capabilities, in the event of a fire, the system can lift the state of the access control on its own, so as to facilitate
    the escape of trapped people and the implementation of rescue work of fire personnel.

    3AcrelEMS-IDC data center integrated energy efficiency management system 3.
    1 program constitutes Accory Electric closely follow the development form of the data center, launched the data center AcrelEMS-IDC integrated energy efficiency solution, integrated substation comprehensive self-monitoring, power monitoring, dynamic ring monitoring, intelligent lighting and other subsystem functions, can help users grasp the operation of the data center in real time, to ensure the safe and reliable operation of the data center, Assist O&M teams to improve data center energy efficiency, resource utilization, and availability, improve O&M efficiency and reduce O
    &M efficiency.

    3.
    2 Function Introduction 1) The system home page displays the total energy consumption, power consumption, air conditioning energy consumption, and other energy consumption of the current data center and calculates the real-time PUE value of the current data center, which is intuitively displayed
    in the form of a dashboard.

    2) The substation is comprehensively monitored in real time on the substation of the data center, and the current telemetry, telemetry data and status of
    the distribution system are displayed in a single graph.

    3) Power monitoring power monitoring cloud platform for the characteristics of power supply and distribution system, the implementation of integrated real-time monitoring of 35KV and below power supply and distribution, to provide modern means for the safe operation of the power grid, can achieve unattended
    .

    4) Power quality monitoring power quality online monitoring, can monitor current and voltage harmonic distortion rate, voltage rise and drop temporary interruption and other transient event records, ITIC tolerance curve, etc
    .

    5) Battery monitoring shows the voltage, internal resistance and temperature of the single battery, predicts the remaining time when the battery is loaded, and the abnormal alarm can be set for each battery data to find the battery abnormality
    in time.

    6) The column head cabinet monitoring system can display the electrical parameters of the inlet line and feeder circuit in the precision distribution cabinet, including the current and voltage power and the switching status, and can alarm setting and classify the data, and the data is taken from the precision distribution cabinet measurement module
    .

    7) The energy consumption analysis displays the daily/monthly/annual report of power consumption, and can display
    the specific circuit selection curve chart and pie chart.

    Compare the data center electricity consumption data with year-on-year and month-on-month analysis to view the

    8) Environmental monitoring and monitoring data center temperature and humidity, opening and closing doors, flooding, smoke, noise, gas concentration status and other parameters
    .

    The graph is intuitive and straightforward, and it also supports historical data query
    .

    9) The air conditioning monitoring system can monitor the return air temperature and humidity of precision air conditioning, the temperature of the return water, and can set the temperature and humidity of precision air conditioning to achieve better control effect
    .

    10) Intelligent lighting users can achieve flexible and diverse intelligent control through a variety of control terminals such as control panel, human body induction, illuminance induction, microwave induction, host computer system, touch screen, mobile phone, tablet end and so on
    .

    11) Real-time monitoring of electrical safety electrical contact temperature, circuit breaker contacts, contact arms, busbars and cable connections and other locations installed wireless temperature sensors to monitor the temperature of the contacts, so as to facilitate the early detection of accidents
    caused by temperature abnormalities.

    12) The intelligent fire management cloud platform for fire monitoring is based on the use of smart security, adding equipment and systems
    such as fire alarm system, smart smoke sense and smart fire fighting water.

    Realize the functions
    of fire prevention, fire alarm and linkage control.

    13) Fault alarm alarm events are divided into four levels, display the number of various alarm events through the list, display the number of daily alarms through the bar chart, and provide the total number of alarms and the growth trend
    .

    14) O&M management O&M management function, can be for the main equipment in the data center to carry out inspection and dispatch, shortage, emergency repair and other maintenance work
    .

    3.
    3 Typical hardwareThe following figure is the system topology diagram of the integrated energy efficiency management system of the AcrelEMS-IDC data center, according to the change of energy flow direction and voltage level, the power supply and distribution of the data center needs to go through the user substation, medium and high voltage distribution room, diesel hair room, low-voltage distribution room, battery room and other scenarios, and finally the energy flow to the data machine room to supply power
    to IT equipment.

    The relevant products of Acquarie can be used in the entire power supply and distribution scenario as follows: 5 Conclusions The data center construction is developing in the direction of scale, science, centralization and greening, in this context, Acrey hopes to help data center builders and managers ensure the stable, safe and continuous operation
    of the data center through the AcrelEMS-IDC integrated energy efficiency management system.

    【References】[1] Yu Maoqin, Dai Zhongye, Li Linjun, Cheng Chunsheng.
    Status quo and development of data center power and environmental monitoring system[ J].
    Journal of Chuzhou Vocational and Technical College, 2020,19 (04):70-73.
    Gao Jin, Wei Qi.
    Construction and Optimization of Data Center Power Environment Monitoring System[J].
    Information and Communication, 2020(05):242-244.
    Chen Shihai.
    Design and Implementation of Data Center Power Environment Monitoring System[J].
    Electronic Technology, 2020, 49(02):140-143.
    About author:Ren Yunye, male, currently working in Jiangsu Ankerui Electric Appliance Manufacturing Co.
    , Ltd.
    , mainly engaged in the research and development and application
    of data center related products.

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.