    The oral liquid filling machine is one of the filling machines in the main machine of oral liquid It is mainly used for filling, capping and sealing of easily straightened bottles It adopts local tracking type four head filling, electromagnetic vibration sending cover, three knife centrifugal sealing (or rotating cover), with no bottle filling function The filling and sealing of the machine are combined into one, with advanced design, compact structure and full compliance with the new GMP standard Before using the equipment, first adjust it The adjustment method is as follows: the function of the filling component to adjust the filling component is to timely transport the liquid medicine to each easy to pull bottle through the filling device, one-way valve and needle Therefore, when the needle enters the bottle mouth, it must be appropriate and the filling time must be appropriate 1 Adjust the side cam a to rotate or reverse so that the needle is inserted into the mouth of the empty bottle as soon as it enters the tooth shape position And lift the needle before leaving the tooth position 2 Filling time adjustment: start filling immediately after the adjustable needle of cam B is put into the bottle mouth, and stop filling before the needle leaves the bottle mouth 3 Adjustment of liquid volume: loosen the nut 1 to adjust the ejector rod in D direction, and the liquid volume will increase; adjust the liquid volume in C direction to reduce, and adjust the nut 2 to adjust the liquid volume in F direction to reduce, and adjust the liquid volume in e direction to increase, and pay attention to the limit position of the drug injector during adjustment, so as to avoid damage to the drug injector It is advisable that the spray from the bottom of the drug injector should not be less than 15 mm, and the longer the filling time is, the better Adjustment of the feeding half 1 Adjust the bottle blocking plate a on the feeding half upward to shorten the adaptive feeding stroke; adjust it downward to extend the adaptive feeding stroke 2 Adjust the positioning bottle position left and right to align the bottle position when the movable teeth are running so that the bottle can be smoothly fed into the positioning teeth 3、 Adjust the bottle blocking plate B to make the bottle inlet width about 22 mm Stop device When the tooth plate is moved to move the bottle to the gear position of filling liquid, the convex surface of cam 7 is away from swing plate 6, swing plate 6 is pulled by tension spring 4 and swings clockwise Swing plate 6 drives bottle pressing bolt 2 to move downward until it contacts bottle 3 At this time, adjust the contact of swing plate 6 of steel wire rolling head 5 and adjust the adjusting screw 8 to make the ejector pin 1 extend about 4mm There is an empty bottle in this position , the bottle pressing bolt 2 and the shaking plate 6 continue to move down due to the action of the tension spring 4, until the steel wire rolling head 5 pulls the steel wire to make the top rod bolt 1 separate from the top rod 9, so they can not drive the medicine filling device to work, and the medicine filling will be stopped automatically Upper arm adjustment The machine can be used for rolling 5-500ml bottle caps When rolling bottles of different specifications, just put the bottles of the specifications on the tray, hold the cross arm with one hand, and loosen the nut on the left side of the cross arm with the other hand, so that the cross arm can be lowered or raised until the position of the capping head and the bottle cap is about 20 mm, tighten the screw nut, and then use the Allen wrench with random belt to close the support ring to the cross arm and lock the support ring (note) pay attention to the alignment between the capping head and the bottle cap during tightening Adjustment of V-shaped support block put the bottle into the lower V-shaped support block, unscrew the two screws on the support block, move the bottle and the lower V-shaped block together until the capping head is aligned with the position of the bottle cap, and then tighten the two screws on the V-shaped block The adjustment of capping head the machine is equipped with multiple capping heads, which can be selected according to the size of different bottle caps Try it with a bottle before use 1 If the cover is not tightly rolled, unscrew the lock nut of the cover head, screw out the upper cover head in a counterclockwise direction, and then lock the fixed nut 2 The cap is too tightly rolled and there is a phenomenon of screwing off the cap The lock nut of the upper rolling cover head can be unscrewed and screwed into the upper rolling cover head in a clockwise direction, and then the fixed nut can be locked 3 The lower edge of the bottle cap is not tightly tightened, and the eccentricity of the three rolling heads can be properly reduced according to the actual situation If the retraction is too tight and there is bottle crushing phenomenon, the eccentricity of the three cutter heads can be properly adjusted After that, the specific operation methods are as follows: 1 Put the bottle with the liquid filled and the lid on the lower tray, lean on the V-shaped support block, hold the bottle with one hand, and pull the handle backward and downward with the other hand At this time, the tray will lift the bottle with the support of the bottle until the bottle cap and the capping head are pressed tightly 2 When the bottle cap and the capping head are pressed tightly, the three continuously rotating capping heads rotate for several turns, and then the bottle cap is pressed tightly (note) the motor must run clockwise 3 Push the handle forward to make the cover return to the original position along with the tray, and the whole operation process is completed Repeat the above operation for each bottle cover in the future The above is the correct operation steps of the oral liquid filling machine shared to you today Have you learned?
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.