Correct operation of ultra pure water machine
-
Last Update: 2019-08-12
-
Source: Internet
-
Author: User
Search more information of high quality chemicals, good prices and reliable suppliers, visit
www.echemi.com
There are certain rules when using ultra pure water machine, users need to operate according to these rules First of all, do not enter the working state immediately when using the equipment It needs to be preheated first, wait for ten minutes, and then operate I when the equipment is running for a period of time, the equipment will be heated, which is normal However, after the equipment is running for a period of time, it is necessary to let the equipment rest for a while Thirdly, the working time of using ultra pure water machine is maintained at 8 hours a day, and 10 hours is OK, but the running time is 8 hours a day Then, after a period of use, users need to clean the equipment to restore the original performance of the contaminated equipment At the same time of restoring the performance of the equipment, we should try to ensure the safety of cleaning, and do not harm the ultra pure water machine II Regular cleaning in the daily operation of ultra pure water machine, the ultra pure water machine needs regular back washing During the back washing, the compressed air is used for friction After the back washing is qualified, the machine is allowed to stand for about 10 minutes before normal washing The washing water can only be put into use after it is qualified Do not bring air into reverse osmosis In addition, regularly check and timely replace the precision filter filter to prevent particle pollution of reverse osmosis membrane caused by leakage of filter element due to installation or quality problems Generally, the filter element shall be inspected once a month and replaced once every 2-3 months During operation, check whether there is gas in the precision filter frequently, and do not let air into the reverse osmosis membrane For standby or long-term shutdown of precision filter, protection measures shall be taken to prevent bacteria from multiplying in large quantities 3 When the ultra pure water machine is stopped for a long time, the equipment will be stopped for a long time The steps of the scheme adopted by the user in the case of leaving the post are as follows: drain the water in the ultra pure water machine; Second, the reverse osmosis membrane shall be soaked with the agent formula under the guidance of the manufacturer (for the equipment with online cleaning system, the protective solution can be injected into the reverse osmosis membrane online, and for the pure water equipment without this function, the reverse osmosis membrane shall be removed and soaked in a proper container); third, the air shall be kept in the equipment room In addition, the RO membrane should be cleaned in time when the water yield of the standardized ro installation is reduced by 10%, or the salt content of the produced water is obviously increased under specific conditions, or the pressure difference is increased by 15%.
This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only.
This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of
the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed
description of the concern or complaint, to
service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content
will be removed immediately.