Anaerobic incubator is a device
for bacterial culture and manipulation under anaerobic environmental conditions.
It can provide a constant temperature cultivation condition in a strict anaerobic state and has a systematic and scientific working area
.
Operating culture in an anaerobic incubator can cultivate anaerobic organisms that are difficult to grow, and can avoid the risk of
death from exposure to oxygen when anaerobic organisms operate in the atmosphere.
Therefore, this device is an ideal tool
for anaerobic biological detection and scientific research.
This device is also a good instrument for multi-purpose use, such as changing the mode of operation, providing good growth conditions
for the growth and reproduction of micro-aerobic bacteria.
What are the common failures of anaerobic incubators during operation? First, the fault phenomenon: no power supply 1, fault cause: plug is not plugged in or short line --- troubleshooting: plug in the plug 2, fault cause: fuse open circuit --- troubleshooting: replace the same type of fuse pipe 3, fault cause: power switch bad --- troubleshooting: replace the power switch Two, fault phenomenon: incubator does not open the lid 1, fault cause: set temperature low --- troubleshooting: adjust the set temperature 2, fault cause: probe bad --- troubleshooting: more probe Three, fault phenomenon: operation room, sampling chamber leakage 1, fault cause: bad sealing--- troubleshooting: with soapy water after the leak with 704 seal 2, fault cause: aging rubber band aging --- troubleshooting: replace the rubber band fourth, fault phenomenon: the gas circuit is not open 1, fault cause: gas valve bad --- troubleshooting: replace the gas valve 2, fault cause: leather pipe leakage or fall off --- troubleshooting: replace the leather pipe 3, fault cause: cylinder gas use up --- troubleshooting: replace gas five, fault phenomenon: light is not lit 1, Cause of failure: The starter or light is not on--- Troubleshooting: Replace the starter or lamp 2, Cause of failure: Rectifier burned out--- Troubleshooting: Replace the rectifier