    Commissioning method of automatic liquid filling machine

    • Last Update: 2022-10-13
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    The debugging method of automatic liquid filling machine is automatic quantitative liquid dispensing machine designed by electric, crank, piston type, peristaltic pump and other structures, which is suitable for the quantitative filling
    of hospital preparation room, ampoule, eye drops, various oral liquids, syrups and various water agents.
    The debugging method of the automatic liquid filling machine has the following points: 1, first loosen the nut and then adjust the screw so that the position of the lower fixing rod changes
    .
    Thus, the push and pull length of the syringe has also been changed, so as to achieve the purpose
    of free adjustment of the filling amount.
    The screw is adjusted clockwise to increments and vice versa, with the pointer indicated
    .
    With a 5ml syringe, look at the 5ml side of the label, use the 10ml needle tube to see the label of 10ml while directly looking at the ruler, the pointer quantification, but because the thickness of each needle tube is different, the actual amount of filling has an error, subject to the needle tube scale, you can also use the measuring cup to measure the most accurate
    when starting to dispense.
    2.
    Immediately after the joint, the nut is tightened so that the lower fixing rod and crank are
    firmly fixed.
    3.
    Loosen the nut and determine the correct position
    of the upper fixing rod according to the push and pull length of different syringes.
    After the lower fixing rod is adjusted, turn the crank to turn the syringe to the upper dead point, and then lift the syringe manhole tube up about 2mm to avoid ejecting the needle tube, and then screw the nut tightly before it can be turned
    on.
    4, the machine assembly is error-free after opening the switch, when the machine is working, the crank drives the syringe up and down to pull the pump, adjust the speed knob, choose the appropriate sub-assembly speed, start normal work, adjust the governor knob, clockwise sub-assembly speed is fast, vice versa speed is slow
    .
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.