    Clean workbench is a kind of local air purification equipment, specially used in cleanroom workshop or sterile room and other working environments, the main application industries are industrial laboratories, biological laboratories, medical and health, biopharmaceuticals and other related industries
    .
    1.
    Put the required instruments, utensils, bacteria packs, test tubes, etc.
    into the
    clean bench after sterilization.
    2.
    When using the clean bench, you should start the machine 30 minutes in advance (press the power button), press the setting key to check the setting of relevant parameters and the working status of the equipment, press the UV lamp key to turn on the UV lamp, and deal with the microorganisms accumulated on the surface in the
    operation area.
    When leaving the room where the ultra-clean workbench is located, turn on the UV lamp in the buffer room in turn to disinfect the bacteria
    .
    After the sterilization is completed, the instrument should be turned off for 30 minutes to allow ozone to be converted into oxygen to avoid irritation
    to the operator's body.
    Then press the fluorescent light key to turn on the fluorescent light and start the fan
    .
    is ready to go
    .
    3.
    Personnel should wear disposable masks, hats and medical latex gloves
    .
    4.
    Open the sliding door
    of the ultra-clean workbench appropriately.
    Take the required action
    .
    During the whole test process, the experimenter should operate in accordance with the sterile operation procedure 5, after the work is completed, wipe the purification work surface with 75% alcohol, turn off the blower, turn on the UV lamp to sterilize for 15min, and then turn off the power
    .
    6.
    After use, fill in the use record
    .
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.