Calibration basis for salt spray corrosion test chambers
Time of Update: 2022-10-01
The error caused by the water droplets falling on each measuring cylinder when opening the salt spray corrosion test chamber.
The error caused by the water droplets falling on each measuring cylinder when opening the salt spray corrosion test chamber.
-
Anaerobic incubator instructions
Time of Update: 2022-10-01
8) The third replacement of the operation chamber (mixed gas displacement) (the mixture gas ratio is H2 1/85% H2 1/10% H2 1/10% CO2/15%) (1) The transfer and exchange path opens the intake of the mixing valve in the operating room, and the sampling chamber is first evacuated when flushing, and pay attention to closing the exhaust at any time according to the exhaust valve.
-
Introduction to the initial tack performance measurement instrument of adhesive products
Time of Update: 2022-10-01
Constant temperature initial viscosity testing machine Model: CNY-1H serial number Technical parameters 1 Equipment use: for self-adhesive, rubber, plastic, textile, waterproof materials, non-woven fabrics and other non-metallic materials and wires, metal foils, metal sheets of tensile, peeling, tearing, compression and other mechanical properties test.
-
Freeze-drying does not destroy the original chemical structure and morphology of the sample
Time of Update: 2022-10-01
Lyophilized products of low-temperature lyophilizer are spongy, non-drying, good rehydration, very little moisture, and can be stored and transported at room temperature for a long time after corresponding packaging.
-
The reform of new drug review and approval has changed, and the innovation and development of biological drugs have accelerated
Time of Update: 2022-10-01
In 2021, Cytiva and Longitude, the research arm of the Financial Times, released the Global Biopharmaceutical Resilience Index, which surveyed biopharmaceutical executives and healthcare industry dec
-
The frontier track of investment and financing blowout may give birth to a number of top and cutting-edge companies
Time of Update: 2022-10-01
The quality of the industry's prospects can be seen from the financing situation. This can be verified in the field of emerging technologies. Take the field of cell therapy as an example. According t
-
Is Mindray okay?
Time of Update: 2022-10-01
The world is full of coincidences and resonances, and since the launch of the sequel to "A Song of Ice and Fire" on August 21, the cold of the coming winter has immediately enveloped the market. Kill
-
Some factors affecting the working accuracy of fully automatic digital granulator/digital microcomputer
Time of Update: 2022-10-01
Or when producing tablets and capsules, due to the large amount of dust carried by the material, the accumulation of dust in the detection channel obscures the infrared rays, so that the counting circuit cannot work normally.
-
Installation and commissioning of walk-in high and low temperature alternating laboratories
Time of Update: 2022-10-01
Whenever possible, install the walk-in high and low temperature test chamber close to the power supply.
Whenever possible, install the walk-in high and low temperature test chamber close to the power supply.
Whenever possible, install the walk-in high and low temperature test chamber close to the power supply.
-
Battery film puncture strength tester Shanghai Chengwei Load sensor: resolution of 0.01 N
Time of Update: 2022-10-01
Executive standard: GBT 37841-2019 Plastic film and sheet puncture resistance test method GB/T36363-2018Polyolefin separator for lithium-ion batteries GB/T21302-2007 Composite film for packaging, bag general rules Technical parameters: Measuring range: (0-50) N resolution: 0.
-
What is the difference between a comprehensive drug stability test chamber and a drug stability test chamber?
Time of Update: 2022-10-01
It is suitable for the stability investigation test of drugs and new drugs in pharmaceutical enterprises, and meets the technical conditions of accelerated test, long-term test and high and low temperature damp and heat test stipulated in the new version of GMP, FDA, ICH principles.
-
Powder top spray granulation fluidized granulation coating machine
Time of Update: 2022-10-01
2 inlet air temperature (°C) room temperature ~ 120 adjustable noise dB (A) ≤ 75 implementation of standard JB/T20073-2013 fluidized bed granulation coating machine dimensions (mm) 1450× 930× 2000 whole machine weight (Kg) 300Powder top spray granulation fluidized granulation coating machine 1 set 1, functional requirements (cargo use): for powder top spraying granulation, particle drying, pellet product coating.
-
Biotech, don't want to grow up
Time of Update: 2022-10-01
At the end of 2019, Kewang loaned 150 million yuan for the construction of GMP production base in Suzhou When the factory was completed, Ji Xiaohui, CEO of Kewang, said that the completion of Suzhou's process development and pilot base was "the first step towards industrialization".
-
What are the characteristics of the distribution intelligent peristaltic pump
Time of Update: 2022-10-01
WT300F distribution intelligent peristaltic pump functions and features: true color LCD screen display, touch screen button operation flow mode, liquid volume distribution, time allocation, copy distribution four modes can be selected Three distribution modes can be pre-stored five sets of allocation parameters start and stop, positive and negative, full speed, speed regulation, state memory and other functions of flow display, flow control, flow cumulative speed resolution 0.
-
How to choose the right powder filling machine?
Time of Update: 2022-10-01
Third, the important maintenance parts (1) power unit (motor) (2) transportation system software (extruder screw, belt conveyor) (3) air pressure system (the application of air compressor test moisturization and sealing) (4) automatic control system (maintenance of the electronic control cabinet, this part should be solved under the specific guidance of the technical engineer)First, the powder filling machine model selection regulations (1) First, we should determine the goods to be filled.
-
ELISA tests the manual washing operation
Time of Update: 2022-10-01
In addition to some ELISA test instruments equipped with special automatic washing instruments, manual operation has two types: immersion type and running water flushing type.
In addition to some ELISA test instruments equipped with special automatic washing instruments, manual operation has two types: immersion type and running water flushing type.
-
Pharmaceutical-grade silica 10kg/bag fumed precipitation method
Time of Update: 2022-10-01
Pharmaceutical grade silica 10kg/bag Pyrogenic precipitation method Pharmaceutical-grade silica 10kg/bag Pyrogenic precipitation silica EryanghuaguiSilicon Dioxide SiO2-χH2O [14464-46-1] This strain r
-
CAS:273222-06-3University laboratory supply, quality assurance
Time of Update: 2022-10-01
, Ltd. shop to view the structural formula: Other similar products: 2-phenyl azetane 22610-18-0iodomethyltrimethylsilane4206-67-1DBCO-C6-acid1425485-72-8(large package purchase-C)4,4, 4-Trifluorobutyric acid 406-93-9 Recapabu(AG-014699)459868-92-9(S)-1-Boc-azetidine-2-carboxamide105443-94-52-(2-naphthyl)ethylamine hydrochloride2017-67-63-(N-methyl-N-BOC-amino)azetane 577777-20-94-(Aminomethyl)- N-methylbenzamide HCl1158467-80-11-bromo-4-(difluoromethyl)benzene 51776-71-73-(4-pyridyl)-DL-alanine 1956-21-44-[(Phenylmethoxy)methyl]piperidine HCl301226-92-64-(N-Boc-N-methylamino)benzoicacid263021-30-32-(N-BOC-N-methylamino)benzoic acid 141871-02-53-methoxy-1-(2-bromoethyl)benzene2146-61-4tert-butyl (3-azidopropyl)carbamate129392-84-32, 3-O-Isopropylene-D-red ketone lactone 25581-41-31-Boc-3-(carboxymethoxy)-pyrrolidine88952-88-9N-CBZ-2-morpholinecarboxylic acid 135782-21-73-Hydroxy-1-pyrrolidineacetic acid258530-57-3[4-(Boc)aminopiperidine-1-yl]acetate 299203-94-45-carboxytetramethylrhodamine 91809-66-43-amino-N-tert-butoxycarbonylalanine 96895-04-4FMOC-(2-aminophenyl) 1185303-23-43-Iodomethyl-3-methyloxetane 112823-30-0BOC-BETA-cyano-L-alanine45159-34-02-(Cyclopropylamino)ethanol35265-06-64' -Fluoro-biphenyl-4-amine324-93-6(1-Bromo-2,2,2-trifluoroethyl)benzene434-42-4(Iodomethyl)cyclopentane27935-87-13-(N-methyl-N-BOC-amino)azetane 577777-20-9Chinese name: (2S, 4R)-Fmoc-4-tert-butoxycarbonylaminopyrrolidine-2-carboxylic acid English name: (2S, 4R)-Boc-4-amino-1-Fmoc-pyrrolidine-2-carboxylic acid;(2S, 4R)-1-(((9H-Fluoren-9-yl)methoxycarbonyl)-4-(tert-carbonoxycarbonyl).
-
How do industrial investors balance science and capital issues after 6 years of entrepreneurship?
Time of Update: 2022-10-01
As an innovative pharmaceutical company initiated by an industrial investor, Dongfang has slightly developed after 6 years, how to balance science and capital?
As an innovative pharmaceutical company initiated by an industrial investor, Dongfang has slightly developed after 6 years, how to balance science and capital?
-
Catheter power injection flow and pressure tester CSI-Z060-1 Shanghai Chengsi - Technical parameters
Time of Update: 2022-10-01
Technical parameters: 1, test pressure: 0-10MPA adjustable, error is not more than ±5% 2, test flow: 0 ~ 500ml, error is not more than ±5% 3, water temperature: 37 degrees Celsius, error is not more than ±1 degrees Celsius 4, data storage: 200 groups 5, constant temperature bath: shape 310-280-180, 15 liters room temperature +8 degrees ~ 100 degrees 6, external size: 760mm-600mm-560mmFlow and pressure tester in catheter power injection product introduction: the use of 7-inch Velon Tong touch screen.