The reactor control device laboratory provides cold source and heat source supporting equipment, refers to the reactor jacket in the heat transfer oil for heating, and the heat energy is indirectly transferred to the heating kettle in the material, thereby controlling the heating temperature of the reaction material, the high use temperature of the equipment can reach 300 degrees
.
1, closed type, high temperature no fumes, low temperature automatic rehydration, switch between high temperature and low temperature at any time, can meet the needs of
rapid heating or rapid cooling on site.
2, the temperature control mode is convenient, you can control the jacket or control the material, the two modes can be switched arbitrarily, can meet the needs of a variety of control needs
on the site.
3.
While meeting the PID control, the accuracy is high, and the inlet and outlet temperature of the oil circuit, the temperature in the kettle, the speed of the stirring, the monitoring of each alarm point, with communication, can be monitored and controlled remotely on the microcomputer, and can be set for segmented time-sharing control
.
4.
The temperature sensor on the reactor body is connected, connected to the heating system switchgear and the three-way valve, and connected to the oil pump on the oil supply pipe and the oil return pipe; Reactor supporting equipment electronic control cabinet and power supply connection; The oil supply pipe output of the heating system is connected with the output pipe of the cooler through the three-way valve, and the outlet of the three-way combined valve is connected with the reactor inlet pipe through the pipeline; Its circulating oil pump is located on the oil return pipe; Its replenishment pump is located on the oil replenishment pipeline between the oil storage tank and the
expansion tank.
5, according to the requirements of electrical wiring, the switchgear, measuring instruments, protection appliances and auxiliary equipment are assembled in a closed or semi-closed metal cabinet or on the screen, its layout should meet the requirements of the normal operation of the power system, easy to overhaul, does not endanger the safety of people and surrounding equipment control cabinet (box).
Including (distribution cabinet) (distribution box) (electrical control cabinet), etc.
, normal operation can be connected or disconnected by manual or automatic switch
.
Cut off the circuit or alarm
with the help of protective appliances in the event of a fault or non-normal operation.
The measuring instrument can display various parameters in operation, and certain electrical parameters can also be adjusted to indicate deviations from normal working conditions or signal
.