    Several common faults and solutions of pill making machine

    • Last Update: 2022-08-20
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    The pill making machine is mainly used for the production of Chinese herbal medicine pills
    .

    It can efficiently produce dense pellets, concentrated pellets, water-tight pellets, coating, drying and pellet-like products produced by food processing
    .

    The machine has stable performance and is easy to operate, clean and maintain
    .

    The other parts that are in contact with the medicine are made of stainless steel material, which meets the requirements of GMP standards.
    When producing pills of different sizes, the size of the spout can be changed and a pill-making knife of different sizes can be used
    .

    The following editor will briefly introduce several common faults and solutions of the pill making machine, as shown below: The power must be cut off before the following operations can be performed 1.
    Phenomenon: When the motor is working, the motor suddenly stops rotating
    .

    Reason: (1), the capacitor is open circuit
    .

    (2), the gear is stuck
    .

    Solution: Check the gear slot for debris and clean it
    .

    2.
    Phenomenon: When the pill is machined, the shaft knife rotates or the medicine surface sticks to the groove
    .

       Reason: The discharge stopper is loose, and there is a distance from the bottom of the shaft knife, so the pills cannot be scraped off the shaft knife groove
    .

       Solution: Adjust the distance between the discharge plate and the bottom of the shaft knife slot (about 0.
    1mm) and tighten the fixing screw
    .

       3.
    Phenomenon: The heater fails to heat up
    .

       Cause: The plug is loose or the power cord falls off; Solution: Replace the plug of the same specification or repair the power socket; 4.
    Phenomenon: The machine produces abnormal noise during the operation.
    Reason: (1) The friction between the shaft knife and the body is dry and no Oil; (2), there is no oil between the gears
    .

       Solution: (1) Put a few drops of clean edible oil into the oil eye; (2) Apply a small amount of butter to each gear groove
    .

       5.
    Phenomenon: After the machine is powered on, the motor does not run
    .

       Reasons: (1), the power cord is in poor contact or the power plug is loose; (2), the switch is in poor contact
    .

       Solution: (1) Repair the power supply or replace the plug of the same specification; (2) Repair or replace the switch of the same specification
    .

       6.
    Phenomenon: When the machine is working, the shaft knife slightly jumps
    .

       Cause: The screw of the compression block is loose Solution: Open the upper cover and tighten the 6 socket head cap screws evenly
    .

     
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.