Isolated tcu temperature control system is a combination of high, medium and low temperature heat source in one equipment, suitable for chemistry, biology, physics laboratories, is biochemical, chemical, scientific research, polymer engineering and other laboratories of cold and heat source equipment
.
Isolation tcu temperature control system operating specifications: 1, the isolation tcu temperature control system is placed in a room with good ventilation and heat dissipation, according to the manufacturer's regulations to connect the power cord
.
The 380V equipment also checks the phase sequence to ensure that the wind direction of the fan is blowing towards the compressor
.
2.
When refueling, the circulation outlet valve should be opened, the inlet should be closed, and the venting valve should be opened
.
When the exhaust valve drains the air clean, close the valve, and open the inlet valve to complete the cycle! 3, turn on the power, the display table is not lit after the power is turned on
.
The Smart Meter can only be displayed after the Run switch is turned on! Heating and cooling
can now be turned on.
4.
Press the refrigeration switch, start the cryogenic compressor, and the cryogenic test begins
.
From 200 °C cooling to -40 °C can be continuously cooled, the isolated TCU temperature control system adopts PID control mode to greatly improve the temperature control accuracy of the whole machine.
The refrigeration or heating with temperature setting microcomputer will automatically change the work, simplifying the operation procedure and avoiding damage
to the machine by misoperation.
5.
The fully enclosed pipeline system is basically isolated from the outside oxygen to reduce the oxidation of the heat transfer oil, and is equipped with the oil mist cooling function
.
Heat transfer oil inevitably produces oil mist when working at high temperatures, and if it is not cooled in time, its service life
will be greatly shortened.
With this cooling function, the service life of the oil is not only extended, but also the circulation pressure is reduced and the flow
rate is increased.
6, isolated tcu temperature control system The entire liquid cycle is closed, with an expansion vessel and a liquid level display, the user finds that the liquid level is low when the heat transfer oil
is replenished.