echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Biochemistry News > Biotechnology News > New biosensor measures toxic drugs in cancer, arthritis and organ transplant patients

    New biosensor measures toxic drugs in cancer, arthritis and organ transplant patients

    • Last Update: 2021-12-26
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com


    Picture: Kirill Alexandrov, Professor of Synthetic Biology, Queensland University of Technology

    Source: Queensland University of Technology

    Researchers have taken another step towards transforming a global diagnostics industry worth 70 billion US dollars


    Researchers from the CSIRO-QUT Synthetic Biology Consortium, in collaboration with Clarkson University and Queensland University of Pathology, demonstrated their modular approach to building small molecule biosensors-designed to capture selected biomarkers and generate measurable Reactive artificial protein


    In two independent studies, biosensors were used to accurately measure the immunosuppressive drugs cyclosporine A, tacrolimus, and rapamycin, and the anticancer drug methotrexate, which requires close monitoring to reduce toxicity and Organ damage


    Lead researcher Professor Kirill Alexandrov said that this protein biosensor has the potential to expand patient care by performing complex tests on cheaper laboratory equipment and new point-of-care equipment


    Professor Aleksandrov said: "Protein is the core of the global $70 billion diagnostic market, which relies heavily on the processing of the central laboratory


    "Our biosensor technology will enable tests such as therapeutic drug monitoring to be performed on less complex devices, and you are more likely to find these devices in small, regional or remote laboratories and hospitals


    Future tests may require even smaller biological samples.


    Professor Aleksandrov said: "With further development, biosensor technology can be used for finger testing.


    Professor Aleksandrov said that the complexity and fragility of proteins have brought difficulties to the construction and use of protein biosensors, but the modular design helps to alleviate this problem and can be adapted to any small molecule.


    He said that the new protein is produced by engineered bacteria and is modified by recombinant DNA technology to produce artificial switch molecules to identify specific drugs


    "Protein biosensor is'turned off'-like a circuit is missing


    When activated, different protein biosensors will produce color changes to read hue-based readings, or generate electrochemical currents


    Professor Aleksandrov said that their team conducted application experiments with ordinary blood glucose meter technology to develop a cheap, portable, and accurate device


    He said: "The activated electrochemical biosensor breaks down glucose and produces electrons as a byproduct, producing an electric current proportional to the number of target molecules captured


    "The Clarkson team also demonstrated the feasibility of reusing this technology to detect two different biomarkers at the same time


    Despite the success of the experiment, Professor Aleksandrov said that blood glucose meter technology is for specific purposes, and researchers need to redesign equipment and manufacturing processes to adapt to new clinical applications
    .

    "When manufacturing medical devices, there are a lot of parameters that need to be coordinated
    .
    This is very difficult, which is why new diagnostic technologies enter the market very slowly
    .
    "

    Professor Aleksandrov is from the Genomics and Personal Health Center, Agriculture and Bioeconomics Center, and the Faculty of Science at Queensland University of Technology
    .
    He said that future research will focus on the stability, sensitivity and manufacturability of protein biosensors
    .

    Article title

    Design of a methotrexate-controlled chemical dimerization system and its use in bio-electronic devices



    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.