echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Active Ingredient News > Blood System > NEJM: Suspended Amyloid Degeneration - Case Report.

    NEJM: Suspended Amyloid Degeneration - Case Report.

    • Last Update: 2020-08-22
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    The patient, a 61-year-old man, went to the hematology department for difficulty swallowing.
    also described a two-year history of swelling of hands and faces, as well as dryness and de-incidence of skin.
    examination of the mouth and pharynx found large tongue disease, fan-shaped, tongue bow erythema, overhanging swelling.
    biopsy of the dangling, the Congolese red dye found apple green double refraction suggesting amyloid deposition.
    analysis of immune tissue showed that the level of the circulatory radcode light chain increased.
    immune-fixed serum electrophoresis showed monoclonal peaks of 0.4 g/dL.
    Free's light chain level is 56.6 mg/L (reference range is 8.3 to 27.0), the ratio of radon to light chain is 3.3 (reference range is 0.26 to 1.65) and proteinuria (24-hour urine sample 0.26g) is elevated.
    bone marrow flow cytometer examination found that 0.54% of the plasma cells had atypical derometers, and the cardiac magnetic resonance imaging examination suggested that amyloid proteins were affecting the left myocardial heart muscle.
    amyloid degenerative disease is characterized by abnormal protein deposition in extracellular tissue.
    light-chain form of disease, extracellular tissue originates from the immunoglobulin light chain associated with plasma cells.
    the patient received an introphysic bone marrow transplant and had a good response to the treatment.
    .
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.