The microcomputer temperature control system has just begun to be installed, and it feels that the cooling effect is not very good, or it has been running for a period of time, and the cooling effect is not good, then it may be that there is a problem with the quality of the purchased machine, so how should we find the problem
.
1, microcomputer temperature control system has many accessories, such as compressor, condenser, expansion valve, heat exchanger, temperature controller, circulation pump, pre-cooling unit, heating unit, refrigeration unit, etc.
, each component has its own role and advantages
.
2, microcomputer temperature control system evaporator and condenser respectively play a role in heat absorption and exothermic, sufficient and suitable heat exchange can give full play to the efficiency of the compressor, if the heat exchange of the condenser is insufficient, it will directly affect the refrigeration effect of the unit, summer is prone to high pressure and even due to high pressure exceeding the standard caused by equipment unit protection shutdown
。 3, in the heating up, the temperature is not reduced, and in a state of almost no change, then it is likely that in the installation process, the installation between the cooling tower, circulating water pump and pipeline of the equipment may have some small problems, you need to arrange personnel to carefully follow the installation diagram to check whether it is caused
by this aspect.
4.
In addition, it is necessary to check whether the thick impurities attached to the pipe affect the flow
of water.
If maintenance is not carried out regularly, it is easy to cause a large amount of dust accumulation in the internal components of the equipment, and it is not effective to dissipate heat, and in the high-load operating state, the natural cooling effect is not as good as before
.
5, and the evaporator heat exchange is more important, insufficient heat exchange will not only cause the unit efficiency is low, serious small will make the refrigerant can not completely evaporate, directly back to the compressor to cause liquid strike, damage the compressor, so that the entire equipment can not be used
.