    Home > Medical News > Medical Research Articles > Master the high-speed filling machine common problems, in addition to ensure the stable operation of the equipment

    Master the high-speed filling machine common problems, in addition to ensure the stable operation of the equipment

    • Last Update: 2020-01-21
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
      Pharmaceutical Network Technical Article: In the packaging machine market, high-speed filling machine is a common equipment, mainly used for the easy-to-cap (or aluminum plastic cap) straight tube bottle filling, lid, seal, so in health care products, medicine and other industries widely used At present, the market of high-speed filling machine noise low, stable operation, environmental protection and energy saving, with ultra-high cost-effective, and many manufacturers can provide customized services, greatly meet the user's filling needs
    In recent years, with the aging, people's consumption level continues to improve, health care products, medicine and other industries rapid development, high-speed filling machine market has also been a good development opportunities At present, the market of high-speed filling machine products are rich in products, each manufacturer's products have their own characteristics, can well meet the needs of the domestic market However, in the choice of high-speed filling machine, users also need to shop around, do not be greedy for a while cheap, ignore the credibility of manufacturers, equipment quality and other issues, so as not to purchase equipment soon after the failure frequency, short life and other issues, affecting normal production, to the production schedule and maintenance costs of enterprises to bring a certain impact
    In addition, there are high-speed filling machine manufacturers remind that users on the high-speed filling machine operation, need to pay more attention to prevent the emergence of problems "Users also need to be tested and debug regularly while maintaining and using high-speed filling machines correctly Only in this way can the filling machine maintain a healthy and stable job What are the common problems with high-speed filling machines in operation? The factory technicianmade a brief list of issues and solutions to share
    FAQ I, high-speed filling machine after the off use, the phenomenon of ground leakage Technicians said that if the user found that the high-speed filling machine after the completion of production leakage phenomenon, should be operated from the following aspects
    First to see whether the filling mouth mouth is damaged or not, the filling nozzle dressing hole can be taken out, the diameter of the hole should be less than 7.5mm After repairing the aperture, gently smooth the hole plane on the water scrub paper Then check whether the ball valve in the filling head is damaged, damage and replace the ball valve
    FAQ 2, high-speed filler sprunafter shank does not function properly after power-up What should be done in this situation?
    Technical personnel give the treatment scheme, that is: the filling machine fixed rod down, the syringe push fluid when the inside and outside the tube top fast, so that the crank can not be rotated, should spin the nut, the upper fixed rod moveupd up the appropriate position, the nut will be tightened If the syringe is assembled causing a non-clean and stuck between the inner and outer tubes, the syringe should be removed for cleaning Observe that the end of the injection system is loaded into the bearing area and, if it does not work properly, need to be reloaded
    FAQ III, high-speed filling machine failure capacity error, or capacity error is large It is reported that in this case generally need to be adjusted by the user
    Technicians pointed out that the filling machine liquid pipe has air, users can press the foot switch to vent, if the inlet pipe seal is not strict, there is leakage, need to clamp the connection pipe, if the operation or filling speed is too fast, the appropriate slow speed, if the fluid tank level is low, will keep the fluid level at 1.52 meters In addition, the user fills large specifications, if the filling tank is insufficient, resulting in instability of the liquid level, you can increase the amount of replenishment or re-close the small irrigation head ball valve, reset the filling time.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.