    Horizontal ribbon mixer is widely used in chemicals, battery raw materials, coatings, dyes, pesticides, pharmaceuticals, food, feed, additives, refractory materials, new materials, electronic plastics, ceramics, fertilizers, metallurgy, mining, dry mortar, special building materials Mixing of powder and solid, powder and liquid in various industries
    .

    The maintenance instructions of the horizontal ribbon mixer are as follows: 1.
    The reducer and bearings should be replaced with lubricating oil regularly during use.
    The lubrication of the reducer should be carried out according to the requirements of the reducer manual
    .

    Lithium complex grease for spindle bearings; 2.
    The particle size of the mixed material is 20-1400 mesh; the amount of liquid spray can be determined according to the adsorption performance of the material and the user's production process requirements; 3.
    The mixing time of a material is generally about 5-8 The mixing time of special materials needs to be determined by the user's test; 4.
    When the horizontal ribbon mixer equipment is running, no hard foreign matter larger than 5mm should enter the machine, otherwise it should be stopped and eliminated
    .

    If abnormal noises such as metal impact and friction are found during operation, it should be stopped in time to check and eliminate; 5.
    When mixing solid-liquid, it should be operated first, and then sprayed.
    After spraying, continue to operate and mix for 3 to 5 minutes.
    Yes; 6.
    The shaft end is sealed with packing, and the sealing material is generally oil-impregnated asbestos.
    If a small amount of leakage is found during use, the packing bolts should be tightened
    .

     
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.