Inhalation preparation drug tester one, the implementation standard in line with YY/71743-2021 for the instrument of the standard two, technical parameters 1.
The flow rate from 15L/min to 100L/min adjustable; 2.
Contains 7 layers of impactor and a micro-hole collector; 3.
With 8 movable collection cups; 5.
The impactor contains a pre-separator, which can be used to detect inhaled aerosols, inhaled sprays, inhaled powder aerosols and inhaled liquid preparations
.
The pre-separator can effectively remove large particles of 10-15 μm generated by the dry powder inhaler; 6.
The collection cup is the impact surface, placed on the tray, directly below the nozzle; 7.
The dose uniformity test
of inhaled powder aerosol, inhaled aerosol and inhaled spray can be completed.
8.
The artificial throat is made of stainless steel, and the size meets the requirements
of the pharmacopoeia.
9.
The pre-separator is made of stainless steel, with a pore diameter of 12.
80±0.
05mm, which meets the requirements
of the pharmacopoeia.
10.
First-stage nozzle, pore diameter 14.
30±0.
05mm, in line with the requirements
of the pharmacopoeia.
11.
Secondary nozzle, pore diameter 4.
88±0.
04mm, in line with pharmacopoeia requirements
.
12.
Three-stage nozzle, pore diameter 2.
185±0.
02mm, in line with the requirements
of the pharmacopoeia.
13.
Four-stage nozzle, pore diameter 1.
207±0.
01mm, in line with pharmacopoeia requirements
.
14.
Five-stage nozzle, pore diameter 0.
608±0.
01mm, in line with pharmacopoeia requirements
.
15.
Six-stage nozzle, pore diameter 0.
323±0.
01mm, in line with the requirements
of the pharmacopoeia.
16.
Seven-stage nozzle, pore diameter 0.
206±0.
01mm, in line with pharmacopoeia requirements
.
17.
MOC nozzle, pore size of about 0.
07mm, in line with pharmacopoeia requirements
.
18.
The small collection cup is made of stainless steel, the depth value is 14.
625±0.
1mm, and the surface roughness (Ra) is 0.
5~2μm in line with the requirements
of the pharmacopoeia.
19.
The large collection cup is made of stainless steel, the depth value is 14.
625±0.
1mm, and the surface roughness (Ra) is 0.
5~2μm in line with the requirements
of the pharmacopoeia.
20.
Intelligent pump, the flow rate is adjustable from 0 to 90L/min, the pumping time is adjustable from 0.
1S to 9999S, and the noise ≤ 75dB
.