    How should the explosion-proof control box be installed? The explosion-proof protection grade is IP65
    .

    It is suitable for flammable and explosive occasions, such as coal mine, chemical industry, petroleum, electric power and other industries.
    It has the characteristics of high safety factor, strong operation function and stable performance
    .

    Explosion-proof control box installation specifications: 1.
    There are two types of explosion-proof control box installation methods: wall-mounted and floor-mounted.
    2.
    Before installation of the explosion-proof control box, check whether the technical data on the nameplate is consistent with the actual use, and check whether all fasteners are loose.
    If there is any looseness, it should be tightened, and the internal and external grounding of the junction box must be good and reliable; 3.
    The selection of the explosion-proof electrical control box of the explosion-proof control box is very important.
    fit
    .

    When installing the explosion-proof electrical control box, the rubber sealing ring in the cable entry device should not be lost, and the compression nut should be tightened.
    Whether the technical data of the junction box is consistent with the actual use situation, check whether all the fasteners are loose, if they are loose, they should be tightened.
    The internal and external grounding of the junction box must be good and reliable; 5.
    The circuit installation of the explosion-proof control box is the assembly of the electric control cabinet Part of, in order to do a good job in the installation work, it is necessary to understand the basic installation information knowledge, in order to install better
    .

    If you want to know more about explosion-proof control box assembly, you are welcome to pay attention to explosion-proof control box manufacturers, here not only provide you with the latest industry news, but also provide explosion-proof electrical equipment and other equipment; 6.
    Small wiring section for explosion-proof control box lines The area cannot be less than 1.
    5 square, and the current loop cannot be less than 2.
    5 square
    .

    If this standard cannot be achieved, the line must not be able to withstand a large current, and the service cycle will be shortened, unable to meet its use requirements
    .

    Therefore, when selecting the circuit, it must be selected according to the specifications, so as not to affect the explosion-proof control cabinet and not work properly
    .

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.