    Spray dryer is also a kind of continuous atmospheric pressure dryer, which is used to dry heat-sensitive liquids, suspensions and viscous liquids, and is also used to dry fuels, intermediates, soap powders and inorganic salts
    .
    At present, the cleaning and maintenance of pharmaceutical equipment are increasingly valued by pharmaceutical companies, but different pharmaceutical equipment has different cleaning methods
    .
    At present, there are three cleaning methods of centrifugal spray dryers, namely dry cleaning, wet cleaning and chemical cleaning
    .
    Among them, dry cleaning mainly refers to the use of brushes, brooms, vacuum cleaners, etc.
    for cleaning
    .
    Chemical washing methods can be divided into lye, acid and various detergents for
    cleaning.
    And so-called wet cleaning is not literally a simple rinse
    with water or disinfectant.
    Wet cleaning refers to the use of hot water with a temperature in the range of 60 to 80 degrees Celsius, cleaning the centrifugal nozzle of the centrifugal spray dryer, and the hot water in this range can ensure that the nozzle is cleaned and disinfected more thoroughly
    .
    In fact, in addition to the above methods, there are also cleaning methods using chemical agents such as pickling and alkaline cleaning
    .
    Among them, pickling refers to the preparation of nitric acid into a solution at a concentration of 1-2% and then heating
    it.
    Alkaline washing refers to the preparation of sodium hydroxide into a solution with a concentration of 0.
    5-1%, and then heated to 60 to 80 degrees Celsius, washed it, and then rinsed with
    clean water after cleaning.
    It should be reminded that when the staff is cleaning the centrifugal nozzle, attention should be paid to the protection measures for the centrifugal spray dryer and centrifugal nozzle, and chlorine and its compounds shall not be used for washing to avoid oxidation
    .
    In addition, if some faults are encountered, the operator should also solve them in time so as not to reduce the service life of
    the equipment.
    If wet powder is adhered to the inner wall of the main tower, it is likely that the feeding speed of the material is too fast and the amount is too large, so that it cannot be completely dry, and the solution is to slow down the speed and quantity of feeding and properly adjust
    the feed pump.
    It is also possible that the operator did not operate according to the requirements of the manual, the main tower was not heated, and the solution was to increase the temperature of the inlet and outlet of
    the spray dryer.
    If a large number of impurities are encountered in the product, it means that the spray dryer material contains impurities, which are not filtered out during filtration, and the air filter can be inspected, and the filter screen is replaced
    according to the situation.
    It is also possible that the purity of the material liquid is not high, and the material liquid can be sampled and tested, and the impurities in the feed liquid can be filtered out
    .
    It is also possible that there are impurities in the equipment, and the operator needs to regularly clean the equipment comprehensively to remove impurities
    .
    The phenomenon of powder running is serious, it means that the recovery rate of the product is low, mainly for two reasons, one is the cyclone problem, the solution is to check the cyclone to see if there is a gap, and whether the air tightness is intact
    .
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.