    Balloon dilatation catheter is a special kind of balloon.
    The balloon can use the delivery system of the catheter to send the balloon to the diseased part, and the diseased part can be expanded
    .

     Balloon dilation catheters are often used to treat vascular diseases.
    Balloon dilation catheters are mainly composed of balloons, dilators, catheter bases and guide wires
    .

    In the treatment of vascular diseases, a small hole with a diameter of about 25 cm is usually left between the catheter and the balloon, which can be used to replace the catheter and guide wire, and is also convenient for treatment
    .

    During treatment, a dilation catheter is implanted into the blood vessel as a therapeutic conductor
    .

    During the treatment, the guide wire can be passed through the catheter several times to unclog the blood vessel, but the catheter does not need to be replaced
    .

    When replacing the balloon dilatation catheter, the original guide wire can be retained, and the quick-exchange balloon basically does not need to be replaced
    .

    Coronary artery stenosis in patients with coronary artery disease is more serious
    .

    Of course, the current interventional treatment of coronary artery disease is generally after balloon dilation, and then implanting a stent, through the support of the stent, the stenosis disappears
    .

    In conclusion, balloon dilatation catheter is a special device for interventional therapy
    .

    Therefore, the balloon dilatation catheter is very important, and its physical performance detection is a very important link
    .

    The main testing instruments are balloon reliability tester, guide wire bending resistance tester, guide wire tip flexibility tester, catheter vacuum residue and leakage tester
    .

    KKO325-C Balloon Reliability Tester KKO325-C Balloon Reliability Tester is mainly used to measure the physical properties of the catheter balloon, and is one of the important means to identify the reliability of the catheter balloon
    .

    It is composed of PLC+ARM programmable controller, Chinese touch screen, force sensor, transmission device, on-board printer, etc.
    , and additional production units are added, and the production batch is input by machine, so that the test results are more standardized and standardized
    .

    KKO325-C Balloon Reliability Tester's detection and control range includes: nominal specification, pipe wall, span, set load, print setting, test, up, down, time, calibration and other function settings
    .

    It is also equipped with an on-board printer to display test results and strength data in real time
    .

    Automatically judge the test results, start the automatic alarm for unqualified, and print out the test data and results by the printer for analysis
    .

     KKO325-C Balloon Reliability Tester Technical Parameters: Operation Interface: Simplified Chinese/English Test Standard: YY 0325-2016 Disposable Sterile Urinary Catheter Nominal Specifications: All specifications can be tested; set load: 0.
    01~50N , Accuracy: ±0.
    001N; Printing method: 100 times of test data and deviation values ​​can be printed each time
    .

    Product net weight: 15kg Appearance size: 430×290×250 (mm) Power supply: AC110V-220V/50Hz (adaptive wide voltage) Machine power: 70W Programmable controller: PLC/ARM Touch screen: 7 inches K600+ core/dot matrix Type 65 colors 800*480 resolution sensor: high-precision force sensor Force measuring mechanism: built-in printer: airborne needle printer YY0540-C guide wire bending resistance tester YY0540-C guide wire bending resistance tester is mainly used for Determining the physical properties of guide wire bending resistance is one of the important means of guide wire
    .

    It consists of PLC+ARM programmable controller, Linux operating system, Chinese touch screen, force sensor, transmission device, on-board printer, etc.
    It displays test results and load and disturbance data in real time
    .

    Automatically judge the test results, start the automatic alarm for unqualified, and print out the test data and results by the printer for analysis
    .

     YY0540-C Guide wire bending resistance tester Technical parameters: Operation interface: Simplified Chinese/English Programmable controller: PLC/ARM Test standard: YY0450.
    1-2003 Disposable sterile intravascular catheter accessories Part 1: Nominal specification of guiding device: all specifications can be input arbitrarily
    .

    Bending angle: 0-180 degrees can be set arbitrarily
    .

    Test accuracy: 0.
    1 degrees; bending frequency: 0.
    1 times/min ~ 20 times/min, arbitrary adjustable loading cylinder diameter: 20D, configured according to the standard, easy to replace (D is the diameter of the guide wire)
    .

    Cylinder spacing: 21D ~ 23D, convenient and adjustable; Test times: set arbitrarily (destructive experiment) Test times: 0-100 times of one-way and two-way force can be set arbitrarily
    .

    Printing method: 100 times of test data can be printed each time
    .

    Touch screen: 7-inch K600+ core/dot matrix 65-color 800*480 resolution Sensor: high-precision force sensor    
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.