    Common maintenance methods of small spray dryer peristaltic pump 1.
    Check whether the various pipelines of the peristaltic pump are smooth, whether the hose joint is loose, and whether the small spray dryer manually rotates the pump head and roller, whether it is flexible
    .
    2.
    Power on the peristaltic pump drive to check whether the motor is running normally, and test whether the peristaltic pump and outlet pressure meet the required requirements after normal operation 3.
    Set the head and flow of the peristaltic pump to ensure that it runs within the best range in order to obtain the operating state
    .
    4.
    In the operation of peristaltic pump, the high temperature of the bearing shall not exceed 80 °C, and ensure that the temperature of the peristaltic bearing shall not exceed 35 °C
    higher than the ambient temperature.
    5.
    During the working process of the peristaltic pump, if the peristaltic pump is found to have abnormal sound, the peristaltic pump should be turned off immediately for inspection
    .
    6.
    Daily maintenance should be timely, the new pump should replace the lubricating oil every 100 hours after one month of use, the peristaltic pump should replace the lubricating oil every 100 hours within the working month, and then every 500 hours.

    7.
    Regularly check the pressure block on the pump head, if the small spray dryer finds that the upper pressure block is rough and uneven, the pressure block on the pump head should be replaced immediately to avoid greater wear of the hose resulting in a decrease
    in the service life of the hose.
    8.
    If the peristaltic pump is not used for a long time, then it is necessary to disassemble the pump head of the peristaltic pump, wipe the other liquids in the pump body, and fully fill the lubricating oil of the connection between the pump head and the drive, the motor bearing and other related parts, and then put it in a safe storage
    environment at room temperature.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.