    Application of Presens Sensor Plugs in Microfluidics

    • Last Update: 2022-09-10
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    In this study, we hypothesized that the sensor system could be used for non-invasive real-time monitoring of microglial metabolism to further elucidate the level of polarization of specific phenotypes in dynamic microenvironments
    .

    We designed and fabricated a microfluidic chip for culturing microglia under continuous flow and correlated changes in oxygen and pH with polarization states upon activation
    .

    Inflammation is a complex series of events triggered by stimuli such as foreign antigens, pathogens, and chemicals
    .

    It plays a key role in a variety of diseases, such as autoimmune diseases, cancer and wound healing processes [1]
    .

    Macrophages and microglia play important roles in inflammation and neuroinflammation, respectively, due to their antigen presentation, phagocytosis, and immunomodulatory properties [2]
    .

    Microglia, as a subtype of macrophages, also function like macrophages in neuroimmune responses [3]
    .

    Depending on the signals they are exposed to in the physiological microenvironment, microglia can transform into two distinct phenotypes, termed M1 and M2 [4]
    .

    Pro-inflammatory M1 microglia, also known as "classically activated", can be induced by lipopolysaccharide (LPS), while IL-4 and IL-13 induce an "alternately activated" anti-inflammatory M2 phenotype [5,6]
    .

    Metabolic changes have been shown to occur in macrophages and microglia in response to stimulation of the M1 phenotype
    .

    During LPS stimulation, the production of nitric oxide (NO) inhibits oxidative phosphorylation, causing the cell to switch to glycolysis
    .

    Due to this reaction, lactate production increases, which in turn increases the extracellular acidification rate (ECAR)
    .

    Monitoring pH changes can provide insight into the physiological and metabolic states of cells and tissues [7]
    .

    The polarized state of microglia can often be detected by gene expression, cell surface markers, and proteins released into the culture medium or accumulated in the extracellular matrix
    .

    PCR, flow cytometry, ELISA and Western Blotting are among the most common methods in this regard, which are invasive, laborious and time-consuming
    .

    These techniques also cannot provide insight and real-time monitoring of changes in polarization states
    .

    In vitro experiments
    .

    Microfluidic organ-on-chip systems provide an excellent in vitro platform to simulate complex organs/tissues by providing heterogeneous cell populations with a 3D layered architecture with dynamic culture models
    .

    Neuroinflammation models of diseases with complex etiologies have been reported previously, further highlighting the advantages of bioengineered microenvironments [8]
    .

    Materials and Methods The microfluidic chip was made of polydimethylsiloxane (PDMS) because of its flexibility, facilitating insertion of sensor plugs and sealing leaks
    .

    To fabricate the PDMS components of the chip, PDMS was cast on polymethyl methacrylate (PMMA) molds with a 1:10 mixture of curing agent and PDMS, respectively
    .

    After degassing under vacuum, bake the mold at 80 ºC for one hour, then cut pieces from the mold
    .

    Chip A is a hybrid chip that includes both PMMA and PDMS components
    .

    The bottom of the chip contains a channel for 3D culture and fluid flow with a PDMS layer on top of these layers with inlet, outlet and sensor plug ports
    .

    An additional layer of PMMA surrounds the chip, providing structural support for the cable, facilitating compression of the bolt
    .

    All these layers are held together with the help of 6 bolts (Fig.
    1C)
    .

    Chip B has two layers
    .

    After soft lithography, the fabricated PDMS components were plasma bonded to microscope slides
    .

    After bonding, the chips were placed on a hot plate at 120°C for 2 hours to enhance bond strength
    .

    Figure 1: Images of two differently fabricated microfluidic chips for 3D and 2D microglia polarization
    .

    Design of chip A for 3D cell culture: A) AutoCAD drawing, dimensions in [mm], B) layers of chip A from top to bottom, C) chip with blue dye and sensor plug dummy Image of A, Chip B designed for 2D cell culture: D) Dimensions of Chip B, E) Number of layers of Chip B, F) Image of Chip B with red dye and sensor plug dummy
    .

    The N9 mouse microglia cell line was used for macrophage polarization experiments
    .

    Cell expansion was performed using complete RPMI (phenol-free) medium 1640 supplemented with 10% fetal bovine serum (FBS) and 1% penicillin/streptomycin (Pen/Strep)
    .

    Cells were grown to 80% confluency and harvested with 0.
    25% trypsin-EDTA
    .

    Ethanol-sterilized chips were seeded with high cell density (4.
    5 x 10 5 cells/cm 2 ) and incubated overnight at 37 °C and 5% CO 2 under static conditions
    .

    Once the microglia adhered and formed a monolayer culture, they were administered using a syringe pump (Harvard Instruments) at a continuous flow of 0.
    5 µl/min (Figure 2)
    .

    Microglia were polarized to an M1-like phenotype with 300 ng/ml lipopolysaccharide (LPS) for 24 hours
    .

    Unstimulated cells were used as a control throughout the study
    .

    Place the microfluidic chip in the cell incubator and connect the sensor plug to the fiber optic cable
    .

    Collect oxygen and pH sensor measurements for 24 hours
    .

    During data acquisition, the incubator was not opened to avoid any gas and temperature fluctuations
    .

    Figure 2: Experimental setup: A) image of sensor connected to fiber optic instrument and computer, B) image of syringe pump and chip, C) chip inside incubator and connected fiber optic cable
    .

    Figure 2: Experimental setup: A) image of sensor connected to fiber optic instrument and computer, B) image of syringe pump and chip, C) chip inside incubator and connected fiber optic cable
    .

    After 24 hours of dynamic culture in the microfluidic chip, lysis buffer containing 15 µM dithiothreitol (DTT) was pipetted into the channel to lyse cells
    .

    Lysates were collected and stored at -80°C for RNA isolation
    .

    RNA was isolated using the Macherey-Nagel RNA isolation kit
    .

    The control and M1 groups were compared based on their TNFα, IL-6 and iNOS gene expression levels by qPCR analysis
    .

    The supernatant collected from the outlet of the microfluidic chip during the 24 h incubation was used for ELISA
    .

    The Affymetrix eBioscience Mouse TNFα Kit was used according to the manufacturer's instructions
    .

    To validate our sensor readings and confirm M1 polarization, we determined the levels of TNFα released in the control and M1 groups
    .

    Results Dissolved oxygen showed a decrease in LPS-stimulated microglia and unstimulated controls
    .

    Although there were similar trends in both conditions, oxygen levels in M1-polarized microglia were lower than in controls during the 24-h stimulation period
    .

    For LPS-stimulated cells, the dissolved oxygen levels of the control were reduced by 22.
    2% and 29.
    5% (Fig.
    3A)
    .

    In the pH monitoring chip, pH levels dropped over 24 hours with a final value of 6.
    8 for the control and 6.
    5 for the LPS-stimulated cells
    .

    Figure 3: Sensor data of O2 and pH profiles during 24 h stimulation
    .

    A) O 2 % change in control and LPS-stimulated cells, B) pH change in control and LPS-stimulated cells
    .

    Gene expression analysis of TNFα, IL-6, and iNOS at the end of 24 hours showed significant fold changes, confirming M1 polarization of LPS-stimulated microglia under dynamic microfluidic culture
    .

    ELISA assay showed a significant increase in TNFα cytokine release from LPS-stimulated cells (M1)
    .

    TNFα concentrations after 24 hours under dynamic conditions were measured as 102 pg/ml for unstimulated controls and 470 pg/ml for LPS-stimulated microglia
    .

    Figure 4: mRNA expression in control and LPS stimulated cells
    .

    A) TNFα mRNA expression in control and LPS-stimulated cells, B) IL-6 mRNA expression in control and LPS-stimulated cells, C) iNOS mRNA expression in control and LPS-stimulated cells
    .

    *P≤0.
    05, **P≤0.
    01, ***P≤0.
    001
    .

    P-values ​​were calculated from a two-tailed Student's t-test
    .

    Figure 5: Concentration levels (pg/ml) of TNFα in media collected from control and LPS-stimulated chip outlets
    .

    *P≤0.
    05, **P≤0.
    01, ***P≤0.
    001
    .

    P-values ​​were calculated from a two-tailed Student's t-test
    .

    Discussion The original purpose of this study was to observe the metabolic changes that occur in microglia during polarization in 3D culture
    .

    To this end, we designed and fabricated Chip A for 3D dynamic culture and stimulated cells to develop towards the M1 phenotype
    .

    We observed that cells in 3D cultures were not efficiently polarized compared to 2D cultures
    .

    We conclude that a lower number of successfully polarized cells may not be sufficient to alter overall metabolic measures
    .

    To demonstrate the advantages of novel sensing systems in microfluidic research, we focus on more traditional 2D cultures and discuss the results with the literature
    .

    Therefore, we decided to perform a two-dimensional dynamic monolayer culture within a microfluidic chip
    .

    These results also prompted us to change the microfluidic chip A to chip
    B.

    After 24 hours of stimulation, we ensured the success of M1 polarization by qPCR analysis
    .

    The mRNA expression levels of typical M1 status markers TNFα, IL-6 and iNOS were significantly higher than those in the control group
    .

    Next, we show that stimulated cells actually complete the translation process from the mRNA to the protein level
    .

    To this end, we measured the level of secreted TNFα protein at the outlet of the microfluidic chip by performing an ELISA
    .

    The pH changes are consistent with the literature: in several previous studies, M1 polarization has been shown to lead to lower pH levels because stimulated cells have higher ECAR
    .

    In our study, we were able to observe a much lower pH within the LPS stimulated chip compared to the control chip
    .

    But when we look at the initial pH of the chip, they are different
    .

    This may be due to bubble formation within the microchannels
    .

    Air bubbles affect the dissolved gas concentration within the chip medium, and dissolved gas changes the pH of the medium
    .

    CO 2 affects the medium by lowering the pH, on the other hand, if the medium is exposed to an oxygen-enriched gas, the pH of the medium will increase
    .

    This could explain the higher pH if the control medium was exposed to O2-rich bubbles
    .

    There is another possibility for this difference
    .

    It takes approximately 40 minutes to set up the experiment and start measuring
    .

    Cells were exposed to stimulatory factors prior to measurement initiation
    .

    This may be due to the fact that LPS-stimulated cells reduce the pH of the medium through the formation of iNOS after stimulation [7]
    .

    O levels did not match the literature: LPS stimulation of N9 microglia reduced proliferation rates and altered cellular metabolism, making it glycolysis-dependent
    .

    These changes in cellular metabolism result in decreased oxygen consumption, and due to cell cycle arrest [9] combined with relatively low cell numbers, measurements of dissolved oxygen levels in LPS-stimulated cells are expected to be higher than in controls and must have a tendency to increase 24 hours stimulation
    .

    Our results showed a 7% reduction in oxygen levels in LPS-stimulated cells
    .

    More experiments must be performed to better understand why this divergence from the literature occurs
    .

     
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.